Reference Manual V1.10
Software Versions 3.xx
Page 6
X300-621-110
2.
Specifications
Resolution
Up to 60,000 divisions, minimum of 0.25
V/division
Zero Cancellation
± 2.0mV/V
Span Adjustment
0.1mV/V to 3.0mV/V full scale
Excitation
5 V for up to 4 x 350 or 8 x 700 ohm load cells (4-wire or 6-wire plus shield)
Max to
tal load cell resistance: 3,500Ω (4x350Ω Nontrade 8x350Ω)
A/D Type
24bit Sigma Delta with 8,388,608 internal counts
20 updates/second
Operating Environment
Temperature:
–10° to +50
C ambient (14° to 122° F)
Humidity: 100%
IP69K
Display
LED Backlit LCD with six 20mm (0.8") high digits with units and annunciators
Setup and Calibration
Full digital with visual prompting in plain messages
Digital Filter
Sliding window average from 0.1 to 4.0 s
Zero Range
Selectable from ± 2% to ± 100% Full Scale
Standard Power Input
12 to 24VDC, 9.6,12 and 24V batteries (2.5 VA max)
ON/OFF key with memory feature
Variants
AC
AC Power supply: 110/240VAC 50/60Hz in 12VDC 1.2A out
Battery
12V battery pack (rechargeable NiMH)
Case Materials
PC+Polyester alloy, PBT, Silicon Rubber, SS304 Stand
Packing Weights
Basic Indicator: 2.0kg
Optical Data Communications
Magnetically coupled infra-red communications
Conversion cables available for RS232 or USB
Serial Outputs
RS232 automatic transmit, network or printer outputs.
Transmission rate: 2400, 4800, 9600 or 19200 baud
Functions
Unit switching, counting, manual hold, peak hold, totalising, high resolution, auto tare, display
test
Assignable Function Keys
1
Battery Backed Clock Calendar
Battery life 10 years minimum
Input/Outputs
3 Outputs -
isolated high side drive outputs (400mA each at 12-24VDC)
1 Input
Set points
2
Approvals
4,000 d @0.8uV/d NMI (S-420),OIML R76
10,000d III/III L NTEP 08-072 A1
FCC, CE, C-tick,