72
Checking the lower limit value
Press the [LOWER] key to display the set value.
After checking, press the g/PCS key to return to the mass display.
3.3.2.2 Piece Counting
Use the [g/PCS], [UNITWT], and [RECALC] keys.
Counting Pieces
Use the following procedure to count pieces based on a sample with an arbitrary number of pieces. For
example, to recalculate the unit weight based on 25 pieces and perform piece counting.
Example Procedure
1) Load the container and press [TARE] key or zero the balance.
2) Count 25 pieces and load them on the pan.
Note
: If in gram-display, the gram value of the 25 piece sample is displayed. If in PCS display, the
value is converted into piece display using the previously stored unit weight. The display may not be 25
pieces.
3) Press the numeric keys for 25 and then the [g/PCS] key.
4) Piece count is now displayed in the new unit weight.
Recalculating the Unit Weight
To recalculate the unit weight with the currently displayed piece count, press the [RECALC] key when
the correct piece count is displayed.
Inputting Unit Weight
To input a unit weight directly, (for example, 1.234). Press 1.234 and then press the [UNIT WEIGHT]
key. Set the unit weight in "g". A value using the maximum number of digits displayed by the balance
can be set. Use the decimal point key on the AKB when entering this value.
Recalling the Unit Weight
Press the [UNIT WEIGHT] key.
Switching from g to PCS
Press the [g/PCS] key to switch between the "g" unit and "piece count" unit.
3.3.2.3 Other Uses
Setting the Pretare Value
Example
: Enter 1.234 and press the [TARE] key.
1.234 g is set as the Pretare value.
Note
: Number of decimal places is set as follows: