38
F16
Function
Set the front key input to be allowed.
Display Meaning
F16. 0
The front keys are unlocked.
Setting range
(0 ~ 1)
F16. 1
The front keys are locked.
Note 1. If it is set to 1, some function keys among the front keys cannot be used.
(Print, Hold, Tare, Step, Subtotal, Grand total, Weighing count, Item number, Setup, etc)
F17
Function
Set the use of function key 1
Display Meaning
Setting range
(0~15)
F17. XX
Set function key 1 to the key in the code table.
Note 1. Set the desired functions using <Table 1. Function Key Code>.
(LCD product = "11" and LED product = "0" as the default at the product shipment)
F18
Function
Set the use of function key 2
Display Meaning
Setting range
(0~15)
F18. XX
Set function key 2 to the key in the code table.
Note 1. Set the desired functions using <Table 1. Function Key Code>.
(LCD product = "12" and LED product = "0" as the default at the product shipment)
Table 1> Function Key Code Table
Function Name
Key Code
Function Name
Key Code
Empty 00 Hold 08
Zero Point
01
Battery
09
Gross Weight * Net Weight
02
Item Number
10
Tare
03
High Limit (LCD, SC Only)
11
Subtotal
04
Low Limit(LCD, SC Only)
12
Grand Total
05
Tare Lease
13
Weighing Count
06
Piece Weight Value
(LCD Only)
15
Print 07
F19
Function
Set the use of unit
Display Meaning
F19. 0
The unit is set the ‘kg’
Setting range
(0, 1)
F19. 1
The unit is set the ‘lb’
Summary of Contents for CI-200 Series
Page 1: ...2 ...
Page 11: ...12 2 Specifications in Appearance 2 1 External Dimension CI 200A CI 201A ...
Page 12: ...13 CI 200S CI 200SC ...
Page 13: ...14 2 2 Front Panel Descriptions CI 200A CI 201A ...
Page 15: ...16 CI 200S CI 200SC ...
Page 78: ...79 MEMO ...
Page 79: ...80 MEMO ...
Page 80: ...81 MEMO ...
Page 81: ...82 ...
Page 82: ...83 ...