51
5-3-4. Checker Function
F50
Function
Select the weighing mode (LCD, SC Only)
Display Meaning
F50 0
Not used.
F50 1
Use as the checker mode
Setting
range
(0 ~ 2)
F50 2
Use as the limit mode
[CHECKER MODE]
Weight
Comm
Signal
(Low Limit) (High Limit)
0 kg 50 kg 100 kg
OUT
PUT
LOW
1
0
HIGH
1
0
OK
1
0
Note 1. All the outputs are generated regardless of the stable status.
[LIMIT MODE]
Weight
Comm
Signal
(Low Limit) (High Limit)
0 kg 50 kg 100 kg
OUT
PUT
LOW
1
0
HIGH
1
0
OK
1
0
Note 1. OK signal is displayed only for the stable status.