4.1.3 Capacity & Units (Menu Code 8130)
(Calibration MENU -> 1. Calibration -> 3. Capacity & Units)
You can move page, using [PAGE UP] [PAGE DOWN] key.
Set scale’s Weighing unit, capacity, Interval, Cal Unit.
Caution :
Span calibration must take place after “
Capacity & Units
” setting.
Do not change setting after Span calibration.
No
Option
Setting Value
1
Weighing Unit
Setting Scale Unit
0 : kg
1 : lb
2 : g
2
Capacity
Setting Scale Max Capacity
0 : 6 kg / 15 lb 5 : 300kg / 600 lb
1 : 15 kg / 30 lb 6 : 600kg / 1500 lb
2 : 30 kg / 60 lb 7 : 1500kg / 3000 lb
3 : 60kg / 150 lb 8 : 3000kg / 6000 lb
4 : 150kg / 300 lb 9 : 6000kg / 15000 lb
3
Interval
Setting Usage of Multi-interval
0 : Single Interval
1 : Dual Interval
4
Cal Unit
Setting Calibration Weighing unit
0 : kg
1 : lb
* This setting uses in Span Calibration,