15
⑩
Suppose that the High limit of 70kg and the Low limit of 30kg are set up. In this condition,
OK
lamp is
lighted on if the weight is 40kg,
HI
lamp is lighted on if the weight is 80kg and if the weight is 20kg,
LO
lamp is lighted on. It beeps as fixed on User Setup Mode.
(Refer to Setup Mode Table on page 17)
7-2. Counting comparison function
①
Press the MODE key until
the display shows “CL OFF”.
It means the counting
comparison function is
deactivated.
②
Press the HOLD(
▲
) key to
activate this function, the
display shows “CL ON”.
③
Press the SET key, the
display shows “L00000”.
④
Press the HOLD(
▲
) or
PRINT(
▼
) key to have
number up or down. To enter
next digit, press the
SAMPLE( ) key.
▶
⑤
Press the SET key, the
display shows “H00000”.
⑥
Press the HOLD(
▲
) or
PRINT(
▼
) key to have
number up or down. To enter
next digit, press the
SAMPLE(
▶
) key.