10
⑤
If the display shows “LACK”, the counting result may not correct. (LCD version : Lack of Unit lamp is On) If the
display shows “ LOW”, it is impossible to count samples because the unit weight is too small. (Refer to Table 1)
Model
DB-II 6kg
DB-II 15kg
DB-II 30kg
DB-II 60kg
DB-II 150kg
DB-II 300kg
Range of Lack (Single)
2g
≥
Lack
≥
0.1g
5g
≥
Lack
≥
0.1g
10g
≥
Lack
≥
0.1g
20g
≥
Lack
≥
1g
50g
≥
Lack
≥
1g
100g
≥
Lack
≥
1g
Range of Lack (Dual)
1g
≥
Lack
≥
0.1g
2g
≥
Lack
≥
0.1g
5g
≥
Lack
≥
0.1g
10g
≥
Lack
≥
1g
20g
≥
Lack
≥
1g
50g
≥
Lack
≥
1g
Range of Low
0.1g
≥
Low
0.1g
≥
Low
0.1g
≥
Low
1g
≥
Low
1g
≥
Low
1g
≥
Low
< Table 1 >
⑥
Place parts on the platter, then the display shows the number
of parts. You can also use tare function in counting mode.
4. Percent Weighing Mode
■
The weight is displayed as a percentage of the reference.
OR
①
Press the MODE key until the display shows “PErSEt”. If you
have set reference sample before, the display shows “0.0”.
②
If you want to use container,
place it and press the TARE key.
③
Place reference sample on the platter and press the SAMPLE
key.
The display shows “100.0”.
Make sure that reference sample should be bigger than 3% of
maximum capacity. If it is lower than 3% of maximum capacity,
the display shows
“low”.
In this case, increase the weight of
reference sample and press the SAMPLE key.