background image

 

 

12

 
 
 
 
 
 
 
 
 
 

 Press the MODE key to 

have number increase. To 
move flash to next digit, press 
the TARE key. 

 

Press ZERO key to set up 

HIGH limit. The display shows 
"0.0" and you can change 
these numbers by pressing 
MODE key. If you want to move
to next digit you can go by 
pressing TARE key. 

 

If you set up HIGH limit you 

can go out by pressing ZERO 
key, and you can see "ENd" 
message shortly and "WL 
on" message on the display. 

 
 
 

 

If you set up HIGH limit and LOW limit incorrectly, "Err" will be shown on the display. 

Then you may need to set it up again. For example, LOW LIMIT=69.9 kg and HIGH 
LIMIT=79.9 kg this is incorrect setting because HIGH limit is lower than the LOW limit. 
When HIGH and LOW limit are set as the same or above maximum capacity it still shows "Err" message. 
 
 
 
 
 
 
 
 
 
 
 
 

 If you want to go back to the 

simple weighing mode just 
press MODE key twice. 

 

Suppose that the HIGH limit 

and LOW limit are set up as 
79.9kg and 69.9kg respectively. 
If the weight loaded is 2kg 
between HIGH and LOW limit 
the display shows "OK" and the 
scale continues to beep slowly. 
If the weight loaded is above 
79.9kg, HIGH limit, the scale 
continues to beep rapidly. 

 

 

Summary of Contents for DL Series

Page 1: ...2 ...

Page 2: ...D FUNCTIONS 6 INSTALLATIONS 8 OPERATIONS 9 1 General Weighing 9 2 Weighing with Tare 10 3 Changing Unit of Weight 10 4 HOLD Function 11 5 ComparatorFunction 11 6 AUTO PowerOff Function 13 BATTERYMAINTENANCE 14 ERROR MESSAGE 14 SPECIFICATIONS 15 ...

Page 3: ...4 ...

Page 4: ...5 ...

Page 5: ...and with outstanding performance Your specialty departments can enjoy these high quality reliable CAS products We believe that your needs will be satisfied and you will have reliability This manual will help you with proper operation and care of the DLseries Please keep this handy for future reference NAMES AND FUNCTIONS OVERALL VIEW ...

Page 6: ...ND KEYBOARD KEYFUNCTIONS KEYS FUNCTIONS Used to set the zero point Used to input or cancel the weight of tare Usedtooperatethefollowingsequenceonthedisplay WEIGHT HOLD WLonoroff WEIGHT Usedtoturnonandoffthescale ...

Page 7: ...8 INSTALLATIONS 1 Insert and fasten the bracket support assembly screws 2 Connect the load cell wire and power line to head 3 Insert the support cover into the support 4 Insert and fasten the screws ...

Page 8: ...e sure that platter is empty Otherwise display will show Err an error of initial zero range Please refer ERROR MESSAGE section for more information on page 16 When the weight becomes stable the display shows the stable sign 0 on You may need to make it 0 0 by pressing the ZERO key unless the display indicate 0 0 under the empty platter 1 General Weighing Placeacommodityon theplatter Removethecommo...

Page 9: ...Placeacommodityintothe container thenthedisplay willshowonlytheweightof thecommodity Removecontainerand commodity thenthedisplay willshowtheweightofthe containerwith symbol PresstheTAREkey then displaywillshowthe 0 0 3 Changing Unit of Weight lb kg Press the MODE key first Holding it press the TARE key in the simple weighing mode The display shows the UnIt shortly and then you may select lb kg as ...

Page 10: ...showtheaverage weight Theaverageweight blinkfortwotimes Whentheweightis unstable prestheMODEkey NOTE Stable indication 0 will not display in HOLD mode Removethecommodityfrom theplatter 5 Comparator Function HI LOW Limit Setting PressTAREkeytoactivate thisfunction Thedisplay shows WLON PresstheMODEkeyuntil thedisplayshows WL OFF WLOFF means thatcomparatorfunction isnotactivated PressZEROkeyoncetose...

Page 11: ...imitincorrectly Err willbeshownonthedisplay Thenyoumayneedtosetitupagain Forexample LOWLIMIT 69 9kgandHIGH LIMIT 79 9kgthisisincorrectsettingbecauseHIGHlimitislowerthantheLOWlimit WhenHIGHandLOWlimitaresetasthesameorabovemaximumcapacityitstillshows Err message Ifyouwanttogobacktothe simpleweighingmodejust pressMODEkeytwice SupposethattheHIGHlimit andLOWlimitaresetupas 79 9kgand69 9kgrespectively I...

Page 12: ...ousvalue PresstheTAREkeyuntilthe displayshowsthe AP x0 thatyouwishtotake RefertoTABLE1 PresstheON OFFkey and thenthescalesaveswhatyou programmedandshowsall thesegments countingup 0 to 9 TABLE 1 DISPLAY FUNCTION AP 00 This function does not automatically power off AP 10 This function does automatically power off when the scale is not in use for 10 minutes AP 20 This function does automatically powe...

Page 13: ...on measurement ERROR MESSAGE ERROR REASONS SOLUTIONS Err An error of the initial zero range Set the platter empty Init Problems onAnalog Module Try to turn OFF and ON the scale Call your CAS dealer if still problems OFL Overload on the platter Remove it from the platter Do not put somthing exceeding maximum capacity on the platter UNStA Unstable conditions of scale Make the scale stable conditions...

Page 14: ...TABLE ZERO kg lb BAT NET HI LO OK KEYS ZERO TARE MODE ON OFF FUNCTIONS General Weighing Hold Function Comparator Function DIMENSIONS 540 x 415 x 775mm PLATTER SIZE 395 x 520 WEIGHT 16 kg POWER 1 5V x 6 option C size battery or 9V adapter MINIMUM VOLTAGE OF THE BATTERY about 5 8V BATTERY LIFE Approx 110 hours Alkaline battery TEMPERATURE 10 C 40 C OPTION 1 5V x 6 C size battery is optional NOTE Spe...

Page 15: ...16 MEMO ...

Page 16: ...17 MEMO ...

Page 17: ...18 MEMO ...

Page 18: ...19 ...

Page 19: ...20 ...

Reviews: