4
O.OOOO
3
O.OOO
2
O.OO
1
O.O
0
O
0
Don't use
BIT3
Use Unit message
1
Use
BIT2
3
Don't use
2
DEP-50
1
BIT 0~1
Print type
0
2.1.2. SPAN Calibration Setting (C-3)
(1) Pressing and holding “Calibration Switch” press [POWER] key.
After “CAL” message blinks three times and shows the version of scale, it displays “CAL 1”
message.
(2) Press [ZERO] to display “CAL-3”.
(3) Press [TARE] key and then it displays “zero ” message.
(4) Press [TARE] key and then it displays “midup” message
(5) Load middle weight (ex:1/3 full capacity) on the platform
(6) Press [TARE] key and then it displays “span ” message
(7) Load full weight on the platform
(8) Press [TARE] key and then it displays “middn” message
(9) Load middle weight (ex:1/3 full capacity) on the platform
(10) Press [TARE] key and then it display “CAL 3” message
2.1.3. Gravity Constant Value Setting (C-9)
Current gravitational Acceleration value is set to 9.7994 m/s
2
.
(1) Pressing and holding “Calibration Switch” press [POWER] key.
After “CAL” message blinks three times and shows the version of scale, it displays “CAL-1”
message.
(2) Press [ZERO] to display “C-9”.
Summary of Contents for EB Series
Page 1: ...EB Service Manual 1 2007 06 13 EB SERVICE MANUAL ...
Page 6: ...EB Service Manual 6 2007 06 13 1 4 Dimension ...
Page 9: ...EB Service Manual 9 2007 06 13 1 6 Sealing Method PLATE ...
Page 10: ...EB Service Manual 10 2007 06 13 STICKER ...
Page 22: ...EB Service Manual 22 2007 06 13 4 Exploded View ...
Page 23: ...EB Service Manual 23 2007 06 13 5 Load Cell drawing ...
Page 24: ...EB Service Manual 24 2007 06 13 6 Part Location 6 1 Main PCB Top ...
Page 25: ...EB Service Manual 25 2007 06 13 6 2 Main PCB Bottom ...
Page 26: ...EB Service Manual 26 2007 06 13 6 3 Rear Display PCB Top 6 4 Rear Display PCB Bottom ...
Page 27: ...EB Service Manual 27 2007 06 13 6 5 Terminal PCB Top 6 6 Terminal PCB Bottom ...
Page 28: ...EB Service Manual 28 2007 06 13 6 7 Cal PCB Top ...