12
TROUBLESHOOTING
Phenomenon
Reason
Solution
Battery damaged
Check battery
No display when
Turn on
Battery contact loosed
Tighten the contact
Display flash
Low battery Min.Capacity
Recharge the battery
Can’t trun on & off
【
OFF/ON
】
Abuttun damaged
Check & clean the buttun
Can’t tare
【
TARE
】
Abuttun damaged
Check & clean the buttun
The recharger damaged
Check the recharger
Recharge indicator
Light can’t turn on
The recharger isn’t
plugged ready
Insert plug again
The load is unstable
Stablize the load
Loadcell cable damaged
Check and replace loadcell
Display isn’t stable
The scale in damp
Environment for a long time
Put the scale in dry
Environment
No enough time for heating
the scale after turn on
After turning on, heating
3-5 minutes.
The display don’t show
“0” when empty load
Put the scale on ground for
too long time
Scale should be hung
The error is large
The scale isn’t hung properly
Check the scale and sling
Battery damaged
Replace battery
Battery can’t recharge
Outlet damaged
Replace the outlet
Receiver window is too dirty
Check and clean
Remote distance
shorten
Low battery of controller
Replace controller battery