56
2) Thermal Head sensor
1) The display shows "SEt PoFF".
2) Press
v
key and the display shows "SEt HEAd"
3) Press Enter key and the display shows "SEt 100 HEAd 118"
4) Set heating value (factory setting is 100) deepens on printing darkness.
(for light printing set value below 100, and set value above 100 to get darker results)
NOTE:
Inputting higher number may damage the thermal head.
5) Press Enter key to save and exit. )
3) Gap sensor
Find out the maximum
value of gap sensor
Find out the minimum
value of gap sensor