4 Nomenclature
10
4.2
Display and Indicators
1) VF Display: The front and rear displays on the LP-2 are dot matrix vacuum fluorescent displays.
They will display all information pertinent to operating the scale.
LP-2 Display Window: Sales
1 2 3
4
5
6
7
17
16
8
15
WEIGHT kg
UNIT $ / kg
TOTAL PRICE $
◀
○
◀
<REG> Auto PrePack Shift Ride 12:12:00 PM
This is PLU Commodity Nam
I
0~30 lb x 0.01 lb / 30~60 lb x 0.02 lb, e=d=0.01 lb, 0.02 lb
0~15 kg x 0.005 kg / 15~30 kg x 0.01 kg, e=d=5g, 10g
CAPACITY:
ZERO
STABLE
NET
14
13
12
11
10
9
#
Description
Values
1
Mode indicator
REG, RPK, MGR, ADD, PLU, NET
1
, STR
2
,
LOC, SET, X1, X2, Z1, Z2
2
Print Mode indicator
Auto
3
Auto Clearing status indicator
PrePack, Save, (Blank)
4
Speed key Shift status indicator
Shift, (Blank)
5
Override, Frequent Shopper, &
Discount Status
Ride, FSP, DISC, Disc, 1, 2, 3, (Blank)
6 Multi-function
indicator
Time, date, scale #, department #,
Alt, Temporary Changes, (Blank)
7
PLU Description line
First non-blank line of PLU commodity
8
Total price heading
TOTAL PRICE and money symbol
9
Total price indicator
7 digits USA: 0.00~9999.99
10
Unit price heading
UNIT, money and weigh symbols
11
Unit price indicator
6 digits USA: 0.00~999.99
12
Weight indicator
5 digits
13 Weight
heading
WEIGHT
and weigh symbol
14
Negative weight indicator
-, (Blank)
15 Net-Weight
indicator
◀
, (Blank)
16 Stable
weight
indicator
○
, (Blank)
17 Zero
weight
indicator
◀
, (Blank)
A Gross Zero indication is reached when the Net-Weight indicator is OFF, the Zero-Weight indicator is ON,
the Stable indicator is ON, and the weight reads 0.00 or 0.000.
Summary of Contents for LP-II