Communications Manual Rev 3.21
Software Versions 3.xx
Page 24
003R-618-321
6. Reading Status and Error Codes
6.1. REG_SYSTEM_STATUS
This register contains status information about the indicator.
Bit(s)
Field
Description
31 to 18, 8, 5, 4
RESERVED
Reserved for future use.
17
OverLoad
The weight is above the maximum
allowable weight reading.
16
UnderLoad
The weight is below the minimum allowable
weight reading.
15
Error
Diagnostic error.
Check REG_SYSTEM_ERROR.
14
MenuActive
Setup menus are active. Registers cannot
be written to using
COMM
.
13
Calibrating
Unit is busy calibrating.
12
Motion
Weight is not stable.
11
isCOZ
The gross reading is within ± ¼ of a
division of true zero.
10
isZero
The displayed weight is within the zero
'dead' band setting.
9
DisplayNet
Display is showing NET value.
7
Output1
The setpoint weight is over the setpoint
target.
6
Output2
The setpoint weight is under the setpoint
target.
3 .. 0
InternalErrorCode
Used for Calibration Errors, etc.
Table 6: Register REG_SYSTEM_STATUS Interpretation
The following table lists the values that the InternaErrorCode field may take. It lists
the error message that would be displayed on the indicator’s display if the operation
was being performed using the setup menus.
Display
Message
Code
Value
Description
no error
00
Last operation was successful.
(SPAN) (LO)
01
The load cell signal range (span) is too small for these
settings.
(SPAN) (HI)
02
The load cell signal range (span) is too large for these
settings.
(RES) (LO)
03
The scale build is configured for less than 100
graduations.
(RES) (HIGH) 04
The scale build is configured for more than 30,000
graduations.
(PT.TOO)
(CLOSE)
05
An attempt has been made to place a calibration point too
close to an existing calibration point.
06
The calibration (linearisation) point does not exist.
(LIN.PT) (LO) 07
An attempt has been made to place a linearisation point
below zero.
(LIN.PT) (HI)
08
An attempt has been made to place a linearisation point
above fullscale.
(RES) (LO)
The scale build is configured for less than 100
graduations.
Summary of Contents for X320
Page 1: ...IP69K Washdown Indicator Communications Manual 800 223 4227 www cas usa com U51024290 ...
Page 47: ...Communications Manual Rev 3 21 Software Versions 3 xx Page 46 003R 618 321 Notes ...
Page 48: ...Communications Manual Rev 3 21 Software Versions 3 xx 003R 618 321 Page 47 Notes ...
Page 49: ...Communications Manual Rev 3 21 Software Versions 3 xx Page 48 003R 618 321 Notes ...
Page 50: ...Notes ...