SIDE terminal is used for connecting any external device that operates double gate.
COM terminal is COMMON used for connecting the “ground” of external devices.
SIDE terminal is used for connecting any external device that operates single gate.
Swipe Card terminal is used for connecting any external devices that will operate to
open the gate.
COM terminal is COMMON used for connecting the “ground” of external devices.
Infrared terminal is used for connecting photo electric sensor.
12V DC output is used for connecting photo electric sensor (Continuous output cur-
rent <=200mA).
24V battery output is used for connecting the back up b.
24V battery output is used for connecting the back up battery -.
24V DC output is used for connecting external device. (such as photo electric sensor,
max current output 1A).
GND is used for connecting the “ground” of external devices.
24V DC lamp output is used for connecting flash light +.
24V DC lamp output is used for connecting flash light -.
24V DC lock output—the NF terminal which used for connecting the electric lock.
COM is COMMON used for connecting the “ground” of lock.
24V DC lock output—the NA terminal which used for
connecting the magnetic lock.
24V DC alarm output.
24V DC alarm output.
Motor1 terminal is used for connecting the motor 1 installed
on the gate that opens later and close first. This terminal
connect 1st red wire (from your left hand side to right hand
side).
Motor2 Delay terminal is used for connecting the motor 2
installed on the gate that opens first and close later. This ter-
minal connect 1st blue wire ( from your left hand side to right
hand side). NOTE! If for single gate, the gate motor just can
connect the Motor2 Delay terminal.
AC24V input is used for connecting the transformer.
AC24V input is used for connecting the transformer.
Digital display is used for showing you the setting data.
INC+ is used for figure increase when setting the data.
FUN is used for recorde the data.
DEC- is used for figure decrease when setting the data.
Learning button is used for program/remove remote.
Control board wiring diagram
1 2 3 4 5 6 7
8 9 10 11 12 13 14 15 16 17 18
19
20
20 21
22
22
23
24
25
26
27
28
29
Summary of Contents for STW-000024
Page 5: ...EN 5 Serial Number...
Page 17: ...EN 17 IR IR...
Page 27: ...FR 27 Num ro de s rie...
Page 39: ...FR 39 IR IR...
Page 49: ...DE 49 Seriennummer...
Page 61: ...DE 61 IR IR...
Page 71: ...ES 71 N mero de serie...
Page 83: ...ES 83 IR IR...
Page 93: ...PT 93 N mero de s rie...
Page 105: ...PT 105 IR IR...
Page 115: ...IT 115 Num ro de s rie...
Page 127: ...IT 127 IR IR...
Page 137: ...NL 137 Serienummer...
Page 149: ...NL 149 IR IR...
Page 159: ...PL 159 Numer seryjny...
Page 171: ...PL 171 IR IR...