11 USING THE STOVE
11.1 POWER ON
Before each ignition, make sure that the burn pot is completely empty and correctly positioned in its seat.
To turn on the stove keep the key pressed for a few seconds.
The flame icon will start to flash, during the ignition phase until it remains fixed when the stove is on.
Automatic ignition: the stove is equipped with an automatic device that allows pellet ignition without the use of
other traditional ignitors.
Avoid manually turning on the stove if the automatic ignition system is compromised.
During initial ignition of the stove it is possible to generate unpleasant smells or fumes caused by the evaporation
or drying of some of the materials used. This phenomenon will gradually disappear.
During the first lightings, we recommend that you keep the premises well ventilated.
“Hermetic” series stoves:
Do not leave the fire box door open for prolonged periods whenever you open it to avoid setting off an
audible alarm when the closure sensor detects the door open status.
11.2 MODIFYING THE PARAMETERS
It is possible to change the operating parameters of the stove according to what has already been stated.
The set values will be maintained until the next change, even with the stove off or disconnected from the power
supply.
11.3 SWITCHING OFF
To switch off the stove, keep the
key pressed for a few seconds; the flame icon will go out.
To switch it on again, it is advisable to wait for the stove to cool completely.
It is advisable to turn off the stove strictly following the above and always avoid doing so by unplugging it from
the power supply.
11.4 OPERATION WITH ROOM THERMOSTAT
When the stove is controlled by an external thermostat (or chronothermostat), the installer must have input
configuration 2. In this case,
the stove switches off
when the external thermostat is reached (open circuit).
The stove switches back on
automatically when the temperature falls below the value set on the external
thermostat (closed circuit).
With the first ignition, or if the switch-off has occurred directly from the stove (
key), the stove must
be switched on directly from the control panel.
11.5 OPERATION WITH ROOM PROBE ON THE STOVE
The stove can be switched on/off manually or programmed.
The stove modulates the power according to the room temperature detected by the probe on board (i.e. the
stove attempts to maintain the desired temperature by consuming as little fuel as possible).
If the user has enabled “Eco-mode”, the stove switches off, instead of modulating, when the set
temperature has been reached and switches on again when the room temperature falls below the set
delta (see par. 10.3).
It is possible to set the desired room temperature in the temperature menu
.