35
ENGLISH
5.5.1
Roof exhaust with traditional fireplace
The flue for flue gas discharge must be carried out
in compliance with the UNI 10683 - EN 1856-1-2 -
EN 1857 - EN 1443 - EN 13384-1-3 - EN 12391-1
standards both regarding the dimensions and the
materials used in its construction.
RAMSHACKLE flues, made of unsuitable material
(fibre cement, galvanised steel, etc. with rough,
porous inner surfaces) are illegal and prevent the
stove from working correctly.
The discharge of fumes through a traditional
fireplace (Fig. 5.8) can be done provided that the
chimney is maintained;
If the chimney has a bigger section, it must be
“intubated” with a suitably insulated steel pipe (with
diameter in line with the route) (Fig. 5.9).
Make sure that the connection to the brickwork
chimney is properly sealed.
If the pipes pass through roofs or wooden walls,
you should use special certified transition kits,
commercially available.
A) Windproof cowl
B) Seal
C) Inspect
1) Vermiculite and/or mineral wool.
2) Steel pipes.
3) Closing panel.
Fig. 5.8
1
2
3
Fig. 5.9
Product images are purely indicative
004778330 - 16/07/2020