39
ENGLISH
8 HOME PAGE CONFIGURATION
Depending on the type of installation, the stove must be set according to the most correct configuration for its
operation.
Before starting, the stove must be powered on by pressing the safety switch on the back:
a) Use the arrow keys to go to the set-up menu and press the
key;
b) Select the password “7” with the
key and confirm with the
key;
c) Scroll with the keys and select the submenu
[30]
; “
--0
” will flash;
d) Press the key and enter the value “54” with the keys;
e) Press
to confirm;
f)
The configuration currently in use will be displayed;
g) To modify, press the
key and enter the value of the new configuration with the
keys;
h) Press
to confirm.
After changing the configuration, a communication error message may appear for a few seconds. Ignore
it and switch the stove off with the safety switch on the back, wait a few seconds and switch it on again.
TWO DIFFERENT CONFIGURATIONS CAN BE SET
:
CONFIGURATION 1 (default)
Set this configuration to switch the stove on and off manually or with a program.
The stove will modulate the power according to the ambient temperature read by the probe on board.
It is possible to set the “Eco-mode” function so that the stove switches off or on again according to the
set room temperature.
The antifreeze function can also be set in this configuration.
CONFIGURATION 2
Set this configuration when the stove is controlled by an external thermostat (or chronothermostat).
In this configuration, the stove switches off when the external thermostat is reached.
The antifreeze function cannot be set in this configuration either.
8.1 CONNECTION TO AN EXTERNAL THERMOSTAT
The stove can be connected to a thermostat or chronothermostat.
When the temperature is satisfied the thermostat opens the circuit then turns off the stove.
The external thermostat must be connected to the relevant terminals on the electronic board which are jumpered
in the factory. Disconnect the jumper, therefore, and connect the two thermostat contacts in its place.
It is important to set the stove to
configuration 2
following the instructions in the “Initial configuration” paragraph.
The first time, following the installation of the chronothermostat, the stove must be switched on manually while
the chronothermostat is in the “called” state. This operation is also necessary in the event of a power failure or
if the stove is switched off manually.
To avoid overlapping operating time bands, we recommend disable the stove timer (set to OFF).
004778330 - 16/07/2020
Summary of Contents for LEONARDO 8ET
Page 26: ......
Page 50: ......
Page 74: ......
Page 98: ......
Page 127: ...127 ESPAÑOL Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 004778330 16 07 2020 ...
Page 129: ...129 ESPAÑOL Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 004778330 16 07 2020 ...
Page 133: ......
Page 134: ......
Page 135: ......