6
6814459-R6 EN
NSTALLATION
I
GA0137.eps
Truck Requirements
Truck Relief Setting
152 bar Recommended
241 bar Maximum
Truck Flow Volume
➀
Min.
➁
Recommended
Max.
➂
25L
4 L/min.
8 L/min.
12 L/min.
32L-70L
4 L/min.
16 L/min.
20 L/min.
➀
Cascade L-Series Fork Positioners are compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or
MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid
is not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
➁
Flow less than recommended will result in slow fork positioning
speed.
➂
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
Carriage Mount Dimension (A) ITA (ISO)
Minimum
Maximum
Class II
Class III
Class IV
380.0 mm
474.5 mm
595.5 mm
381.0 mm
476.0 mm
597.0 mm
Carriage –
Clean and inspect carriage
bars. Make sure that bars are parallel
and that ends are flush. Grind smooth
any protruding welds that may affect
sideshifter lower bearings. Repair any
damaged notches.
GA0082.eps
Auxiliary Valve Functions
Check for compliance with ISO
standards:
Hoist Down
Hoist Up
Tilt
Forward
Tilt
Back
Sideshift
Left
Sideshift
Right
Open
Forks
Close
Forks
A
GA0028.eps
Summary of Contents for 25L
Page 23: ...BLANK ...