9 - ACCESSORIES
Operating controls
The flow rate/pressure characteristic of the auxiliary circuit can be set according to the type and to the specifications
of the attachment used.
NOTICE:
before operating any hydraulic attachment be sure to set the proper attachment mode (breaker or crusher)
and the proper hydraulic flow rate/pressure characteristic. If the attachment mode or the hydraulic flow rate/pressure
characteristic are not properly set, malfunction or failure may occur to the machine or damage may occur to the
hydraulic attachment.
To operate the breaker or clamshell, use the auxiliary
pedal
(A)
.
When breaker operating is finished, stop engine and push
the auxiliary pedal
(A)
to release pressure in the breaker
circuit.
If pressure still remains, the lifetime of the diaphragm in
the accumulator will be shortened.
NOTE:
make sure to prevent contamination by dust, sand
and etc. Contaminated oil causes wear and damage to
the moving parts of the pump.
NOTE:
when operating the breaker, bolts and nuts of main
equipment may be loosened by vibration. So, it must be
inspected periodically.
NOTICE:
If not using any hydraulic attachment, do not
operate controls for auxiliary hydraulic circuits.
SMIL16MEX1484BB