6 - MAINTENANCE
Feed pump
To clean the filter of the fuel supply pump proceed as
follows:
1.
Place a container with suitable capacity under-
neath the fuel supply pump (located to the left
and below the fuel main filter).
SMIL13CEX2890AB
1
2.
Close the fuel pre-filter valve
(A)
, then remove
the fuel supply pump.
SMIL13CEX2891AB
2
3.
Open the pump cover, then pull out the filter
(3)
and the seals
(2)
and
(4)
.
4.
Clean the filter
(3)
with compressed air. Check
the filter
(3)
and replace it if necessary. Re-
place the seals
(2)
and
(4)
with new seals.
5.
Carefully clean the body
(5)
and the cover
(1)
.
Never leave any dirt in the fuel supply pump.
6.
Install the seals carefully in the correct order as
you re-assemble and install the pump.
SMIL13CEX2892AB
3
7.
Open the fuel pre-filter valve
(A)
.
8.
Bleed the air from the fuel line.
SMIL13CEX2893AB
4
6-72