DISTRIBUTION SYSTEMS - HIGH-FLOW HYDRAULIC POWER SYSTEM
38.
Stop the vacuum pump.
39.
Disconnect the vacuum pump from the opening in
the reservoir.
40.
Install new hydraulic and hydrostatic
fi
lter elements
on the machine.
41.
Start the engine. Check for oil leakage around the
new hydraulic and hydrostatic
fi
lters.
42.
Stop the engine.
43.
Check the level of the oil in the reservoir and add
oil as required.
Reservoir - Filling (A.10.A.22 -
F.60.A.10)
1 04/05/2005
A.16.A / 8
Summary of Contents for 435
Page 1: ...REPAIR MANUAL 435 445CT 445 6 75491 1 04 05 2005 ...
Page 3: ...INTRODUCTION 6 75491 1 04 05 2005 1 ...
Page 15: ...INTRODUCTION bs04e020_1 4 6 75491 1 04 05 2005 13 ...
Page 16: ...INTRODUCTION bs04e021_1 5 6 75491 1 04 05 2005 14 ...
Page 19: ...REPAIR MANUAL DISTRIBUTION SYSTEMS 435 445CT 445 39702 1 04 05 2005 A ...
Page 86: ...39703 1 04 05 2005 A 10 A 66 ...
Page 104: ...39704 1 04 05 2005 A 12 A 18 ...
Page 126: ...39705 1 04 05 2005 A 16 A 22 ...
Page 127: ...DISTRIBUTION SYSTEMS A ELECTRICAL POWER SYSTEM 30 A 435 445CT 445 39706 1 04 05 2005 A 30 A 1 ...
Page 237: ...DISTRIBUTION SYSTEMS A LIGHTING SYSTEM 40 A 435 445CT 445 39707 1 04 05 2005 A 40 A 1 ...