DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
Reservoir - Filling (A.10.A.22 - F.60.A.10)
435, 445, 445CT
1.
Lower the loader lift arms to the ground and shut
off the engine.
2.
Clean the reservoir
fi
ller cap and the area around
the
fi
ller cap with cleaning solvent.
3.
Turn the
fi
ller cap 1/2 turn to relieve air pressure
from the reservoir. Do not remove the
fi
ller cap from
the reservoir until the pressure is relieved.
4.
Remove the
fi
ller cap from the reservoir.
5.
Add the correct oil
CASE AKCELA AUTO
SUPREME SAE 10W-30
to the reservoir until the
proper oil level in the reservoir is established. Fill
the reservoir until the oil level is at the mid point of
the site gauge.
6.
Start and run the engine and operate the hydraulics.
Lower the loader lift arms to the ground. Stop the
engine and check the oil level in the reservoir. Add
oil as required.
1 04/05/2005
A.10.A / 54
Summary of Contents for 435
Page 1: ...REPAIR MANUAL 435 445CT 445 6 75491 1 04 05 2005 ...
Page 3: ...INTRODUCTION 6 75491 1 04 05 2005 1 ...
Page 15: ...INTRODUCTION bs04e020_1 4 6 75491 1 04 05 2005 13 ...
Page 16: ...INTRODUCTION bs04e021_1 5 6 75491 1 04 05 2005 14 ...
Page 19: ...REPAIR MANUAL DISTRIBUTION SYSTEMS 435 445CT 445 39702 1 04 05 2005 A ...
Page 86: ...39703 1 04 05 2005 A 10 A 66 ...
Page 104: ...39704 1 04 05 2005 A 12 A 18 ...
Page 126: ...39705 1 04 05 2005 A 16 A 22 ...
Page 127: ...DISTRIBUTION SYSTEMS A ELECTRICAL POWER SYSTEM 30 A 435 445CT 445 39706 1 04 05 2005 A 30 A 1 ...
Page 237: ...DISTRIBUTION SYSTEMS A LIGHTING SYSTEM 40 A 435 445CT 445 39707 1 04 05 2005 A 40 A 1 ...