DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
Oil
fi
lter - Remove (A.10.A.24 - F.10.A.10)
435, 445, 445CT
1.
Place a shop towel under the oil
fi
lter.
2.
Remove the cap from the hydraulic reservoir.
3.
Reservoir - Apply vacuum (A.10.A.22 - F.35.A.50)
Connect a vacuum pump to the reservoir.
4.
Start the vacuum pump.
5.
Tag and disconnect all the hydraulic lines to the oil
fi
lter base. Install plugs in the
fi
ttings. Loosen and
remove the wire from the electrical connector.
BD04C143
1
6.
Stop the vacuum pump.
7.
Loosen and remove the mounting bolts and washers
from the oil
fi
lter head mounting bracket.
BD04C143
2
8.
Remove the oil
fi
lter head from the mounting
bracket.
9.
Oil
fi
lter - Visual inspection (A.10.A.24 -
F.40.A.10)