DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM
Connector - Testing (A.30.A.87 - G.40.A.20)
435, 445, 445CT
NOTE:
For wiring diagram refer to
Wiring harness - Electrical schematic frame 06 (A.30.A.88 - C.20.E.06)
Wiring harness - Electrical schematic frame 04 (A.30.A.88 - C.20.E.04)
N°
Test Point
Expected Result
Other Result (Possible Cause)
1 Disconnect the 26 pin connector
from the instrument cluster. Make
sure the ROPS is in the latched
position. Have another person sit in
the operators seat. Place the seat
bar in the down position.
Terminal 14 in the connector to
ground.
85 to 90 ohms coil resistance
Check the circuit between the
connector and the interlock relay
coil. Also check the interlock relay.
Also check circuit for ground wire
178E (B).
2 Turn the key switch to the ON
position.
Terminal 12 in the connector to
ground.
12 volts
Check the circuit between the
connector and the seat switch. Also
check the seat switch.
Also check circuit for wire 130B (R)
to the 15 amp buss bar fuse.
3 Terminal A (258) in the connector to
ground.
12 volts
Check the circuit between the
connector and the brake pressure
switch. Also check the brake
pressure switch
1 04/05/2005
A.30.A / 102
Summary of Contents for 435
Page 1: ...REPAIR MANUAL 435 445CT 445 6 75491 1 04 05 2005 ...
Page 3: ...INTRODUCTION 6 75491 1 04 05 2005 1 ...
Page 15: ...INTRODUCTION bs04e020_1 4 6 75491 1 04 05 2005 13 ...
Page 16: ...INTRODUCTION bs04e021_1 5 6 75491 1 04 05 2005 14 ...
Page 19: ...REPAIR MANUAL DISTRIBUTION SYSTEMS 435 445CT 445 39702 1 04 05 2005 A ...
Page 86: ...39703 1 04 05 2005 A 10 A 66 ...
Page 104: ...39704 1 04 05 2005 A 12 A 18 ...
Page 126: ...39705 1 04 05 2005 A 16 A 22 ...
Page 127: ...DISTRIBUTION SYSTEMS A ELECTRICAL POWER SYSTEM 30 A 435 445CT 445 39706 1 04 05 2005 A 30 A 1 ...
Page 237: ...DISTRIBUTION SYSTEMS A LIGHTING SYSTEM 40 A 435 445CT 445 39707 1 04 05 2005 A 40 A 1 ...