INTRODUCTION
3.
Disconnect the negative battery cable from the neg-
ative battery terminal.
RCPH11TLB003AAM
3
Master disconnect switch (if equipped)
Enable or disable electrical power from the machine bat-
teries to the electrical components using the master dis-
connect switch, located on the right hand side of the en-
gine.
NOTICE:
Wait at least 60 seconds after ignition key is
placed in the OFF position before turning master discon-
nect switch to OFF. This allows the machine controllers to
shutdown properly.
NOTICE:
Some machine service procedures require an
actual terminal disconnect of the batteries. Do not use the
master disconnect for those types of procedures, such as
welding on the machine.
RCPH11TLB002BAD
4
47441594 27/09/2012
9
Summary of Contents for 570NXT