6 - WORKING OPERATIONS
Detent position for 4 in 1 bucket control switch
NOTE:
4 in 1 bucket, if equipped
The operator or a service technician may enable a detent position into the 4 in 1 cycle by adjusting the switch. The
switch comes from the manufacture with the open U shape up. In this configuration, the switch will spring back to
neutral when released from any position.
The detent position will alter the cycle to allow the operator to touch the switch to hold open the circuit until the operator
pulls the switch out.
NOTICE:
Do not leave the switch in the detent position
when the cylinders or attachments are not being oper-
ated, this will cause the hydraulic system to operate over
relief.
Enable the detent position for the switch:
1. Pry off the cap that covers the switch screw.
RCPH10TLB260AAF
1
2. Using a Phillips head screwdriver, remove the screw
that holds the switch.
RCPH10TLB261AAF
2
3. Remove the top of the switch.
4. Rotate the top of the switch
180 °
and start the screw
back into the top of the switch.
NOTE:
The open U shape should be to the bottom.
RCPH10TLB262AAF
3
6-15
Summary of Contents for 570NXT
Page 8: ......
Page 24: ...1 GENERAL INFORMATION 1 16 ...
Page 88: ...3 CONTROLS INSTRUMENTS 3 28 ...
Page 142: ...6 WORKING OPERATIONS 6 34 ...
Page 193: ...7 MAINTENANCE Cylinder closed end Two total one on each side RCPH10TLB258AAF 3 7 51 ...
Page 252: ...7 MAINTENANCE 7 110 ...
Page 257: ...8 SPECIFICATIONS Machine overall dimensions 8 5 ...
Page 259: ...8 SPECIFICATIONS RAIL12UTL0182GA 1 8 7 ...
Page 260: ...8 SPECIFICATIONS 8 8 ...
Page 262: ...8 SPECIFICATIONS RAIL12UTL0182GA 2 8 10 ...
Page 272: ...9 ACCESSORIES 9 4 ...
Page 279: ......