7 - MAINTENANCE
2.
Hold a small container under the water separator and
loosen the drain valve.
3.
Collect a small amount of fluid and inspect for water
or sediment.
4.
Drain until water or sediment is no longer present.
5.
Close the drain valve.
6.
If water or sediment was found in the water separator,
drain the fuel tank.
A.
Place a collection container under the drain
plug and remove the plug .
B.
After water and sediment are removed, install
and tighten the plug.
NOTE:
The drain plug for the fuel tank is underneath the
machine. Illustration shows looking up at the drain plug.