7 - MAINTENANCE
Air conditioning belt
Inspect the tension of a new air conditioning belt after the
first 10 hours of operation and then every 250 hours of
operation.
1.
Check the belt at the location shown with a belt ten-
sion gauge. Specification is
122 - 149 N·m
(
90 - 110
lb ft
).
RAIL11TLB0001AA
1
2.
If the belt tension does not meet specification:
A.
Loosen the pivot bolt
(1)
.
B.
Loosen the lock nut
(2)
.
C.
Turn the adjustment bolt
(3)
clockwise to
tighten the belt.
Turn the adjustment bolt
counter-clockwise belt will loosen.
D.
When adjustment is complete, tighten the lock
nut and pivot bolt.
RAIL11TLB0005AA
2
7-61