DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
6.
Visible contamination is foreign material that can be
found by sight, touch, or odor. Visible contamination
can cause a sudden failure of components. Exam
ples of visible contamination:
(A)
Particles of metal or dirt in the oil.
(B)
Air in the oil.
(C)
The oil is dark and thick.
(D)The oil has an odor of burned oil.
(E)
Water in the oil.
NOTE: The hydrostatic system uses
a
third port bypass fil
ter system. If the filter becomes plugged it bypasses back
to the reservoir to stop contamination from entering the
hydrostatic system. Upon completion of cleaning the hy
draulic system replace the hydrostatic system filter.
87728445 1 2/28/2008
A.10.A / 15