DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
PRIMARY HYDRAULIC POWER SYSTEM - Decontaminating
CAS10162A CAS10508 CAS10192
1.
Prepare the portable filter
CAS10162A
by doing the
following steps:
(A)
Remove all the hydraulic oil from the inlet and
outlet hoses for the portable filter.
(B)
Remove the filter element from the portable filter.
(C)
Remove all hydraulic oil from the portable filter.
(D)
Clean the inside of the housing for the filter ele
ment.
2.
You must know whether the contamination is micro
scopic or visible. Refer to
PRIMARY HYDRAULIC
POWER SYSTEM - Cleaning (A.1 0.A).
3.
If the contamination is microscopic:
(A)
Check the maintenance schedule for the ma
chine to learn if the hydraulic oil must be changed.
If needed, change the hydraulic oil. Change the hy
draulic filter.
(B)
Do steps 6 through 35.
4.
If the contamination is visible:
(A)
Change the hydraulic oil and hydraulic filter.
(B)
Do steps 5 through 35.
5.
Check the amount of contamination in the hydraulic
system by doing the following steps:
(A)
Disassemble one cylinder in two different cir
cuits. Check for damage to seals, scoring of the
cylinder wall, etc. Repair the cylinders as necessary.
(B)
If, in your judgment, the damage to the cylinders
was caused by sever contamination and is not the re-
sult of normal wear, it is necessary to remove, clean
and repair valves, pump, lines, cylinders, hydraulic
reservoir, etc. in the hydraulic system.
6.
Remove the breather from the reservoir and connect
the vacuum pump to the opening. Start the vacuum
pump.
7.
Loosen and remove the drain plug from the reservoir.
8.
Using the fitting kit
CAS10508,
install the valve in the
hole for the drain plug. Make sure that the valve is
closed.
9.
Stop the vacuum pump.
10. Connect the inlet hose for the portable filter to the
valve that is installed in the hole for the drain plug.
11. Disconnect the vacuum pump from the hydraulic
reservoir air breather hose. Remove the filler cap.
12. Install the outlet hose for the portable filter in the hy
draulic reservoir filler neck.
13. Open the valve that is installed in the hole for the
drain plug.
14. Move the switch for the portable filter to the ON po
sition. Start and run the engine at 1500 rpm (r/min).
15. Run the portable filter for 10 minutes.
87728445 1 2/28/2008
A.10.A / 16
Summary of Contents for 750L
Page 1: ...REPAIR MANUAL 750L 850L 87728445 1 2 28 2008 ...
Page 4: ...87728445 1 2 28 2008 Find manuals at http best manuals com search s CASE 87728445 ...
Page 18: ...INTRODUCTION 87728445 1 2 28 2008 14 ...
Page 19: ...REPAIR MANUAL DISTRIBUTION SYSTEMS 750L 850L 87728445 1 2 28 2008 A ...
Page 51: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com ...