4 - OPERATING INSTRUCTIONS
Auxiliary hydraulic circuit flow patterns
Flow patterns can be selected from the 20 shown below.
NOTE:
The number of setting patterns is 10 maximum.
1 flow
2 flows
126 l/min
(
27.7 UK gpm
)
252 l/min
(
55.4 UK gpm
)
117 l/min
(
25.7 UK gpm
)
242 l/min
(
53.2 UK gpm
)
108 l/min
(
23.8 UK gpm
)
234 l/min
(
51.5 UK gpm
)
97 l/min
(
21.3 UK gpm
)
223 l/min
(
49.1 UK gpm
)
85 l/min
(
18.7 UK gpm
)
210 l/min
(
46.2 UK gpm
)
73 l/min
(
16.1 UK gpm
)
199 l/min
(
43.8 UK gpm
)
62 l/min
(
13.6 UK gpm
)
188 l/min
(
41.4 UK gpm
)
51 l/min
(
11.2 UK gpm
)
176 l/min
(
38.7 UK gpm
)
38 l/min
(
8.4 UK gpm
)
164 l/min
(
36.1 UK gpm
)
34 l/min
(
7.5 UK gpm
)
160 l/min
(
35.2 UK gpm
)
Changing the flow patterns
NOTE:
To prevent failure or damage to the tool, make
sure that you select the correct circuit configuration and
flow rate for the tool.
1. Operate the switch
(1)
located on the front right-hand
switch panel to display the flow pattern to be changed.
Every time the switch
(1)
is pressed, one of the differ-
ent types of flow patterns recorded for the pump can
be selected.
VOHLGR-002
30
2. The recorded value can be identified by the number
shown on the screen, e.g.:
(1)
= value 1 in the table.
(2)
= value 2 in the table.
(3)
= value 3 in the table.
3RW3PD-004Z
31
4-43
Summary of Contents for CX145C SR
Page 6: ......
Page 18: ...1 GENERAL INFORMATION 1 12 ...
Page 29: ...2 SAFETY INFORMATION E5054225_TU 4 2 11 ...
Page 132: ...3 CONTROLS INSTRUMENTS 3 82 ...
Page 160: ...4 OPERATING INSTRUCTIONS 4 Operate the arm control to unhook the tool KKZVLU 024A 14 4 28 ...
Page 180: ...4 OPERATING INSTRUCTIONS 4 48 ...
Page 206: ...6 MAINTENANCE Offset boom pin 10 07C803C9 17 6 16 ...
Page 207: ...6 MAINTENANCE Arm backhoe bucket 375EFD72 18 AB1F527A 19 6 17 ...
Page 298: ...8 SPECIFICATIONS Offset maximum left EACB5F36 6 See next page for the value 8 14 ...
Page 300: ...8 SPECIFICATIONS 8 16 ...