6 - MAINTENANCE
2. Remove the nut
(2)
and the cover
(3)
from the
breather.
3. Remove and discard the used filter element
(4)
.
4. Install a new element
(4)
, making sure the seal
(5)
is
facing upwards.
5. Install the cover
(3)
as well as the nut
(2)
.
19IXC6-002
11
Replacing the hydraulic fluid
1. Release all pressure in the hydraulic reservoir. Refer
to page
6-37
.
2. Remove the reservoir cover plate.
3. Using a pump, remove the fluid from the hydraulic
reservoir. Have a container with a suitable capacity
ready.
01268A52
12
6-44