6 - MAINTENANCE
Connecting booster batteries
WARNING
Improper operation or service of this machine can result in an accident.
An error connecting auxiliary starting cables or short-circuiting battery terminals can cause an acci-
dent. Connect auxiliary starting cables as instructed in this manual.
Failure to comply could result in death or serious injury.
W0263A
Make sure that the booster battery voltage corresponds to the voltage system of the machine (24 volts).
1. Place the key of the battery master switch in
“O”
(Off) position (if equipped).
2. Remove the terminal sleeves.
3. Connect the positive
(+)
cable to the positive
(+)
terminal on the first machine battery.
4. Connect the negative
(-)
cable to the negative
(-)
terminal on the second machine battery.
5. Place the key of the battery master switch in
“I”
(On) position (if equipped).
6. Start the engine.
7. Remove the booster battery negative
(-)
cable and then the positive
(+)
cable.
8. Install the terminal sleeves.
6-83