3 - CONTROLS/INSTRUMENTS
Manual regeneration
XNNFHF-001Z
5
Normal operation is disabled in manual regeneration.
When manual regeneration starts, engine revolutions are reduced automatically and the engine sound and hydraulic
operation sound change.
These do not imply any problems.
If operation continues when the orange lamp blinks, the diffuser may be faulty.
Move to a safe place as quickly as possible and execute regeneration.
ATTENTION:
If the switch is not pressed for a long time, the orange lamp changes from slow to fast blinking. If the
switch is not pressed at this time, the engine problem warning lamp goes on and the diffuser needs to be repaired.
NOTE:
Consult your CASE CONSTRUCTION Dealer if a red
DPD
icon is displayed.
Manual regeneration finishes earlier immediately after the machine runs than when the engine is cool.
The water temperature may rise during manual regeneration.
1. The orange lamp blinks.
• The buzzer sounds for 2 seconds.
• The following message is displayed.
Push
DPD
switch to activate
2. Move the machine to a safe place with no combustible objects.
• Set the function cancellation lever to the lock position (safety bar retracted).
• Press the switch.
3. Manual regeneration starts.
• The orange lamp is lit.
• The buzzer sounds for 2 seconds.
• The following messages are displayed cyclically.
Manual
DPD
Re-gen
Do not operate
3-43
Summary of Contents for CX145C SR
Page 6: ......
Page 18: ...1 GENERAL INFORMATION 1 12 ...
Page 29: ...2 SAFETY INFORMATION E5054225_TU 4 2 11 ...
Page 132: ...3 CONTROLS INSTRUMENTS 3 82 ...
Page 160: ...4 OPERATING INSTRUCTIONS 4 Operate the arm control to unhook the tool KKZVLU 024A 14 4 28 ...
Page 180: ...4 OPERATING INSTRUCTIONS 4 48 ...
Page 206: ...6 MAINTENANCE Offset boom pin 10 07C803C9 17 6 16 ...
Page 207: ...6 MAINTENANCE Arm backhoe bucket 375EFD72 18 AB1F527A 19 6 17 ...
Page 298: ...8 SPECIFICATIONS Offset maximum left EACB5F36 6 See next page for the value 8 14 ...
Page 300: ...8 SPECIFICATIONS 8 16 ...