4 - OPERATING INSTRUCTIONS
6. Use the proportional switch to operate the hydraulic
breaker.
NOTICE:
In Bucket mode, do not carry out operation us-
ing auxiliary line. If you do that the warning message
“Auxiliary set-up required” will be displayed with alarm
sound. Stop operation immediately and carry out auxil-
iary set-up.
NOTE:
To prevent failure or damage to the tool, make
sure that you select the correct circuit configuration and
flow rate and pressure for the tool.
EC3339BB
15
Muti-purpose circuit with pressure adjuster
Pedal type
1. Make the necessary tool connections and then, using
a hexagonal wrench, open the supply valves located
at the tip of the arm, left-hand and right-hand side.
VOHLGR-016
16
2. Switch
(1)
located on the right-hand console upwards,
corresponding to the demolition grab.
Every time the switch
(1)
is pressed, one of the differ-
ent types of flow patterns recorded for the pump can
be selected. For the flow and pressure setting method,
refer to page
3-26
.
VOHLGR-002
17
4-33
Summary of Contents for CX300C