Switching between Main Unit and Sub-unit Temperature Data

Press the 

SELECT

 button (

7

) to toggle the display between the main unit (INDOOR) temperature and the sub-

unit (OUTDOOR) temperature.
Main unit temperature:  INDOOR indicator displayed
Sub-unit temperature:  OUTDOOR indicator displayed

The display does not change to the sub-unit (OUTDOOR) temperature if no data has been received from the sub-
unit yet.

Holding down the 

SELECT

 button (

7

) for about two seconds turns on auto display switching (   displayed),

which causes the temperature display to alternate between the main unit temperature and sub-unit temperature
at five-second intervals. To turn off auto display switching (   not displayed), hold down the 

SELECT

 button (

7

)

for about two seconds again.

INDOOR

SELECT button

 (

7

)

Main unit

Sub-unit

OUTDOOR

HYGROMETER FUNCTIONS

Both the main unit and the sub-unit are equipped with their own humidity sensors. Humidity data measured by the
sub-unit is sent by wireless transfer to the main unit. You can toggle the main unit display between the main unit
humidity reading and the sub-unit humidity reading. This makes it possible to view both the indoor and outdoor
humidity on the main unit display.

Humidity Measurements

Both the main unit and the sub-unit take humidity measurements every 16 seconds.

The humidity display shows “LO” for humidity below 10% and “HI” for humidity above 90%.

Switching between Main Unit and Sub-unit Humidity Data

Press the 

SELECT

 button (

7

) to toggle the display between the main unit (INDOOR) humidity and the sub-unit

(OUTDOOR) humidity .
Main unit humidity:  INDOOR indicator displayed
Sub-unit humidity:  OUTDOOR indicator displayed

The display does not change to the sub-unit (OUTDOOR) humidity if no data has been received from the sub-unit
yet.

Holding down the 

SELECT

 button (

7

) for about two seconds turns on auto display switching (   displayed),

which causes the humidity display to alternate between the main unit humidity and sub-unit humidity at five-
second intervals. To turn off auto display switching (   not displayed), hold down the 

SELECT

 button (

7

) for

about two seconds again.

INDOOR

SELECT button

 (

7

)

Main unit

Sub-unit

OUTDOOR

USING THE SUB-UNIT

Data Transfer from the Sub-unit

Data is transferred from the sub-unit to the main unit every three minutes.

The sub-unit is able to send data to the main unit up to an unobstructed distance of about 30 meters.

The data receive status is indicated on the display of the main unit by the icons shown below.

Receive successful

Receive unsuccessful

If a receive operation is not successful for some reason, the display of the main unit shows dashes (–) in place of
the sub-unit temperature and humidity values.

If you experrience problems with data transfer, press the 

RE-SYNC

 button (

6

) to synchronize the two units. If

this does not eliminate the problem,try changing the positions or orientations of the main unit and sub-unit.

The transferred data includes temperature and humidity data.

Switching between Celsius and Fahrenheit

Press the 

°

C/ 

°

F

 button (

A

) to toggle between Celsius (

°

C) and Fahrenheit (

°

F).

°

C/ 

°

F button

 (

A

)

 Celsius (

°

C)

Fahrenheit (

°

F)

Switching between Current Temperature and Humidity

Press the 

SELECT

 button (

8

) to toggle the display between the current temperature and current humidity.

Holding down 

SELECT

 button (

8

)  for about two seconds causes the display to continually toggle between the

temperature and humidity at five-second intervals.

SELECT button

 (

8

)

Temperature

Humidity

Location

Place the sub-unit in a location where it will not be exposed to rain, direct sunlight, or other elements.

USING THE WEATHER FORECAST FEATURE

A built in pressure sensor makes it possible to forecast upcoming weather over the next 12 hours based on
changes in barometric pressure. Note that these forecasts are not absolutely accurate, and are intended for
general reference only.

Weather Forecasts

Barometric pressure readings are taken every 15 minutes. Weather forecasts are based on the last six readings.
Upcoming weather forecasts are displayed using the graphic indicators shown below.

 Sunny

Sunny, some clouds

Cloudy

Rain

Stormy

Upcoming weather trends are indicated as shown below.

 Improving weather

Deteriorating weather

Stable weather

Summary of Contents for IDR-200

Page 1: ...Operation Guide IDR 200 1 MA0406 EA o C o F SET SELECT RESET WAVE RE SYNC o C o F SET SELECT RESET WAVE RE SYNC 1cm ILLUSTRATION Main unit ...

Page 2: ... 2SET button Use this button to cycle through setting screens 3WAVE button Press this button to trigger a time calibration signal receive operation 4RESET button Press this button to reset the clock after replacing its batteries 5 C F button Press this button to toggle the temperature unit between Celsius and Fahrenheit 6RE SYNC button Press this button to re synchronize the timing of the main uni...

Page 3: ...ong or behind mountains Signal reception is normally better at night than during the day Radio interference can make signal reception impossible Strong electrostatic charge can result in the wrong time being set Mainflingen 1200 km USING THE CLOCK Any of the following procedures can be used to set current date and time Auto receive of the time calibration signal Manual receive of the time calibrat...

Page 4: ...4 Be sure to press the RESET button 4 after replacing batteries To replace sub unit batteries 1 Open the stand so you can see the back cover 2 Remove the back cover screw and then open the back cover 3 Remove both old batteries 4 Load new batteries Make sure that their positive and negative ends face in the correct directions If you load batteries incorrectly they can burst and damage the sub unit...

Page 5: ...als To turn off auto display switching not displayed hold down the SELECT button 7 for about two seconds again INDOOR SELECT button 7 Main unit Sub unit OUTDOOR USING THE SUB UNIT Data Transfer from the Sub unit Data is transferred from the sub unit to the main unit every three minutes The sub unit is able to send data to the main unit up to an unobstructed distance of about 30 meters The data rec...

Page 6: ... appliances near office equipment mobile phones or wireless LAN devices Near a construction site airport or other sources of electrical noise underground or in tunnels near railroads highways or radio stations with interfering frequencies Near high tension power lines Locating the sub unit near a device that transmits radio signals using the same frequency as this product can cause communication f...