background image

                                                                                                 
 

 

43 

 

 

About the battery 
1.

 

Do not attempt to disassemble or solder the battery. Also, do not heat or throw the battery into a fire. 

2.

 

When the button-type battery (memory backup battery) used in this terminal is removed, exercise care 
so as not to accidentally swallow it. Remain aware of the danger to infants. Store the button-type battery 
in an infant-safe location. Should the battery be swallowed, immediately consult a doctor. 

3.

 

If the battery is improperly used, the electrolyte may leak and soil other objects, resulting in fire and 
personal injury. Be sure to observe the following precautions: 

4.

 

Make sure of the polarity (+, or -) of the battery when installing it. 

5.

 

Do not leave this terminal unused for an extended period of time with the battery installed. 

 

About the battery pack 
Do not use the battery pack in a place where it will be exposed to static electricity. The battery pack may 
become hot, explode, or ignite. 

 

Avoid exposing it to water and foreign matter 
Should foreign matter (metal chips, water, liquid chemicals) enter inside the product, immediately turn off the 
IT-10, remove the battery pack, and then contact your CASIO distributor. 

 

Memory protection 
1.

 

Contents of the IT-10 should always be backed up in personal computer to make a separate record from 
that on the terminal. The contents of the memory may accidentally be lost due to battery power 
consumption, etc. This also occurs when this terminal malfunctions or is repaired. 

2.

 

When replacing the battery pack, always refer to the user’s guide accompanied in the carton box. 
Improper battery replacement may lead to unexpected loss or alteration of data. 

 

Place of installation 
1.

 

Do not place the IT-10 in an environment with a significant amount of moisture or dust. Otherwise, a 
fire or electric shock may occur. 

2.

 

Do not use the IT-10 in the vicinity of a cooking table, humidifier, etc., where it will be subjected to oily 
smoke or vapor. Otherwise, a fire or electric shock may occur. 

3.

 

Do not place the IT-10 in an unstable situation, such as on a wobbling platform or shelf. It may fall and 
cause personal injury. 

4.

 

Do not throw the IT-10 into a fire. This may cause a fire or personal injury due to explosion of the 
terminal. 

       

 

Summary of Contents for IT-10 - Cassiopeia M20 - Win Mobile

Page 1: ...IT 10 Series Hardware Manual Version 1 00 CASIO Computer Co Ltd Copyright 2005 All rights reserved March 2005 ...

Page 2: ...er 4 Quality References 28 4 1 Environment Performances 28 4 1 1 IT 10 28 4 1 2 HA C60IO 29 4 1 3 HA C61IO 29 4 1 4 HA C32DCHG 30 4 1 5 HA C21BAT 30 4 2 Electric Durability 31 4 2 1 IT 10 31 4 2 2 HA C60IO HA C61IO 31 4 2 3 HA C32DCHG 31 4 2 4 HA C21BAT 32 4 3 Physical Durability 33 4 3 1 IT 10 33 4 3 2 HA C60IO HA C61IO 33 4 3 3 HA C32DCHG 33 4 3 4 HA C21BAT 34 4 4 Reliability 35 4 4 1 IT 10 35 4...

Page 3: ...ny means electronic or mechanical foranypurpose withouttheexpress written permissionofCASIO Computer Co Ltd in Tokyo Japan Information in this document is subject to change without advance notice CASIO Computer Co Ltd makes no representationsor warranties with respect to thecontents or useof this manual and specificallydisclaims any express or implied warranties of merchantabilityor fitness for an...

Page 4: ...4 Editorial Record Manual Version no Date edited Page Content 1 00 March 2005 Original ...

Page 5: ...itable rough handling that any vertical market device will suffer This referencemanual will explain you in detail about the specifications of hardware reliability environment compliance andetc for the series including models IT 10M20 and IT 10M20BR and the dedicated options as well Forsoftwareandlibrary relatedreferences refertotherespective reference manuals releasedon theCASIOWEB site athttp www...

Page 6: ...529 standard Large3 7 inchtransflectiveVGALCD landscape or portrait mode is possible Standard large capacitybatterypack for up to 27hours of continuous use CompactFlash and SDIO card slots for flexible systemexpansion in future possible Auto recovery tool to automatically back up and restore user dataincase of accidental datacorruption Bluetooth andWireless LAN compliant with IEEE802 11b areintegr...

Page 7: ...utput 12V AC adaptor ACAdaptor AD S15050AE DC output 5V 3A ScreenProtectSheet ScreenProtectSheet HA C90PS5 5pcsinonepack CommunicationCard Cover CommunicationCard Cover HA C92TCV RS 232C cable DT 887AXA Length 1 5 m 9 pin male USB cable DT 380USB Length 2 0 m Cable RS 422 cable DT 888RSC Length 1 0 m The accessories in the tablebelow are accompanied as accessoryin each individual carton box ofIT 1...

Page 8: ... AD S42120AE Dual battery Charger HA C32DCHG Battery Pack HA C21BAT WLAN IEEE802 11b Basic Cradle HA C60IO PC Bridge satellite Cradle HA C61IO AC Adaptor AD S42120AE RS 422 SD Card Slot CF Card Slot Serial Port DC Jack Headphone Jack Battery Pack HA C21BAT AC Adaptor AD S42120AE SD card Recommended option CF Card Recommended option IrDA Product Recommended option AC Adaptor AD S15050AE Headphone D...

Page 9: ...9 1 3 General Guide 1 3 1 IT 10 External Views Fig 1 3 2 3 4 5 6 7 9 10 11 1 8 12 13 14 15 16 22 6 18 17 19 21 20 Fig 1 2 RefertoTable1 4fornamesofeachpartand itsdescription ...

Page 10: ...erminal is mounted on the Basic Cradle the lamp turns on in orange indicatingthe batterypack is being charged or in green indicating thebattery pack is fullycharged 13 Indicator lamp right The lamp blinksin green when CFcard or SD card is being accessed It also blinks in red for the alarm 14 Power switch Press this switch to turn on the power or off Once the power is turned on wait for 10 seconds ...

Page 11: ...ector 2 Alignment pegs Align the terminal with thesetwo pegs when mounting itto theBasic Cradle 3 Poweradaptorport ConnectthededicatedAC adaptor AD S15050AE here 4 RS 232C port This port is used when connecting to a PC for data transfer between the terminal and the PC via RS 232C interface 5 USB port This port is used when connectingtoaPCfordata transferbetweenthe terminal and the PC via USB inter...

Page 12: ...12 1 3 3 HA C61IO Bridge Satellite Cradle Views RefertoTable1 6fornamesofeachpartanditsdescription 3 5 4 2 1 Fig 1 5 Fig 1 7 10 9 8 7 6 Fig 1 6 ...

Page 13: ...unication between the terminal and a PCis established Red Connection problemin the Cradle LINE Indicates thesystemstatus Off The systemis not operational 3 Statuslamp Green The systemis operational 4 Power terminals These terminals supplypower tothe terminal mounted onthe Cradle 5 Power switch TurnsonthepowerontheCradle 6 Poweradaptorport ConnectthededicatedACadaptor AD S42120AE tothisport 7 RS 42...

Page 14: ...Flashing green Idle mode waiting for a next charge 1 Charging status indicator lamp Off No batterypack is mounted 2 Powerterminals Thesepowerterminalsprovide power to the mounted batterypacks 3 Poweradaptorport ConnectthededicatedACadaptor AD S42120AE tothisport 4 Seriesconnection terminal Maximum3 units of HA C32DCHG can be connected in series connecting this terminal to the terminal on another H...

Page 15: ...15 1 3 5 HA C21BAT Battery Pack View Fig 1 9 ...

Page 16: ...arekeyboard Keyboard Programkeys x4 Actionkey UP DOWNkeys Cursorkey Switch Powerswitch Resetswitch Batterycoverlock switches x2 IrDA Standard IrDAVersion 1 3 compatible Method Half duplex Synchronization Start stop frame synchronization Baud rate 9600 bps 115200 bps 4 Mbps Comm range 0 contact to 0 3 m WirelessLAN IT 10M20BR Standard IEEE802 11b Modulation Directsequencespreadspectrum DS Frequency...

Page 17: ...um900 mA DC input Input voltage 5V 5 Consumption current 3A Plug EIAJType II AC adaptor AD S15050AE Powerterminals Powerterminals Thepower fromCradle is supplied to the terminal via these powerterminals Headphone jack Stereo headphone jack 3 5 mmin diameter Speaker Monaural Microphone Monaural Power Operating battery Lithium ion batterypack x 1 pc HA C21BATbatterypack Memory backup battery NiMHbat...

Page 18: ...nsions Approx 80 W x140 D x25 H mm Note3 Weight Approx 290g Note4 Notes 1 Concurrent use ofWireless LAN communication and Bluetooth communication is not recommended The communicationrange mayvarydepending on the radio condition in air and or the surrounding environment 2 Each memorybackup period will dependon thecharacteristic of the terminal itself the surroundings including temperature humidity ...

Page 19: ... ADP Power for charging batteryon the terminal See note 16 ADP Power for charging batteryon the terminal See note 17 ADP Power for charging batteryon the terminal See note 18 RS232C RXD RS232C IN 19 RS232CTXD RS232C OUT 20 GND See note 21 GND See note 22 CRSEL0 For recognitionof connected device IN 23 CRSEL1 For recognitionof connected device IN 24 ADP Power for charging batteryon the terminal See...

Page 20: ...eingturnedonis1 10 IT 10M20BR Yes Approx 14hours Thesurroundingtemperatureisatroomtemperature Thebatterypack HA C21BAT isabrandnewand fullycharged Thebacklightisturnedoff TheIrDAsettingissettooff TheCPUspeedsettingisset to AutoMode Theoperatingperiodicratioofidlewith thedisplay beingturnedon RFandcalculationis10 1 1 Notes Thedurationsoftime in Operatinghour for IT 10M20BRhas been measured in the w...

Page 21: ...ronization Start stop method Comm speed 115 2Kbps Applicableto HA C61IOonly Interface RS 422 Connector RJ 45compatible 6pins No ofLEDs 3 No ofdisplaycolors 2 red green Display StatusLED Displaycontent Systemoperationstatus LINE Comm status DATA Powerstatus POWER Applicableto HA C61IOonly RefertoChapter2 4 StatusIndication WithLEDs DIPswitch 8switches RefertoChapter2 3 DIPSwitchSetting ForHA C61IO ...

Page 22: ... HA C60IO InputfromAC adaptor ACadaptor Dedicated AD S42120AE Applicableto HA C61IO Outputvoltage DC5V 10 2 200 mA maximum Applicableto HA C61IO Outputcurrent 1 500 mA maximum Applicableto HA C60IO Charge method Constantvoltage Withcurbfunctionon current Chargetime Approx 5 0hoursorless WhenHA C21BATis installed intheterminal Power Charge supply power Powerterminals Theillustrationofthe powertermi...

Page 23: ...t used always OFF Not used always OFF Host Computer Interface Switch Number 6 RS 232C OFF USB ON Daisy Chain Termination Switch Number 5 Intermediate Connection OFF Daisy Chain Off Termination ON Connection Switch Numbers 3 4 Host Computer OFF OFF Daisy Chain ON OFF Inter Cradle Data Rate RS 422 Comm speed Switch Numbers 1 2 115 200 bps ON OFF Note OtherDIPswitchsettingsareusedfortestingandinspect...

Page 24: ...iption Remark LED Off Poweroff Green PowerisONandtheterminal iscorrectly mountedontheCradle Powerstatus indicator POWER Red PowerisONbuttheterminalisnotcorrectly mountedontheCradle 2 colorLED Off Nocommunicationbeingperformed Green Flashing Communicationisinprogress Comm statusindicator DATA Red Flashing Problemintheconnectionbetween twoBridge SatelliteCradles 2 colorLED Off Thesystemisnotoperatin...

Page 25: ...ks mounted Thesurroundingtemperatureisat roomtemperature Power SuppliedviadedicatedACadaptor AD S42120AE DC12V 5 Approx 0 8A Insingleconfiguration Consumptioncurrent Approx 2 4A Inconfigurationofthree HA C32DCHGsbeingconnected Operatingtemperature 0to40 Operatinghumidity 30to80 Max no ofconnectivity 3unitsofHA C32DCHG Weight Dimensions Table 2 7 Item Specification Remark Weight Approx 170g Dimensi...

Page 26: ...ours Whenchargingtwobattery packsatatimewith HA C32DCHG Operatingtemperature Refertothetemperature for HA C32DCHG inTable 4 4 when charge Refertothetemperature for IT 10inTable 4 1 when discharge Operatinghumidity Refertothetemperature for HA C32DCHG inTable 4 4 when charge Refertothetemperature for IT 10inTable 4 1 when discharge Weight Approx 60g Dimensions 72 8 W x58 0 D x8 1 H mm ...

Page 27: ...ences ofthe terminal The numbers from10 to 14representa manufacturingreference whichisreservedbythemanufacturer Seethefigurebelow foreach meaning 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Production month of the year 1 to 9 A B C Production year last digit only Ex 1 represents the year 2001 Model number two digits in alphanumeric 94 Domestic version 95 Domestic version 97 IT 10M20 98 IT 10M20BR 0A HA C6...

Page 28: ... See IP Industrial Protection code All covers on the terminal are closed whiletesting IP Industrial Protection code Acording systemto indicate thedegrees of protection provided by an enclosure against access to hazardous parts ingress ofsolidforeignobjects ingress of water and to give additional protectionin connection with such protection Elements ofthe IP54 level andtheir meanings are as follows...

Page 29: ... box Temperature 20 to 60 Humidity 10 to 90 RH No condensation Dustandwater splashproof Not applicable 4 1 3 HA C61IO Table 4 3 Item Specification Condition Operation 0 to 40 Temperature Storage 10 to 50 Operation 30 to 80 RH Humidity Storage 30 to 90 RH No condensation Storage in carton box Temperature 10 to 50 Humidity 30 to 90 RH No condensation Dustandwater splashproof Not applicable ...

Page 30: ...ication Condition Operation Refertothetemperature for HA C32DCHG inTable 4 4 when charge Refertothetemperature for IT 10inTable 4 1 when discharge Non operation Refertothetemperature for HA C32DCHG inTable 4 4 when charge Refertothetemperature for IT 10inTable 4 1 when discharge Temperature Storage 10 to 50 Operation Refertothehumidityfor HA C32DCHG inTable 4 4 when charge Refertothehumidityfor IT...

Page 31: ...DC5V 5 ApplicabletoHA C60IO Inputvoltage DC12V 5 ApplicabletoHA C61IO Anti staticstrength Malfunction 6 KV Destruction 12 KV 150pF 330ohm Linenoisestrength Malfunction 1 000V Pulsewidth 5KHz Burstcycle 300msec No ofpulses 75pcs Burstperiod 15 msec Powerinterruption 10 millisecondsorless 4 2 3 HA C32DCHG Table 4 8 Item Specification Remark Approx 0 03A Whenthebatterypackisnotmounted Consumptioncurr...

Page 32: ...32 4 2 4 HA C21BAT Table 4 9 Item Specification Remark Anti staticstrength Malfunction 10KV Destruction 13KV CompliantwithIEC6100 4 2standard fullycharged ...

Page 33: ...ss 10 to 55 Hz In X Y and Z directions Reciprocally for 30 minutes Resistancetovibration in package 1 5 G or less 10 to 55 Hz In X Y and Z directions Reciprocally for 30 minutes Resistance to impact In bare condition 70 cm One time for 6 faces onto concrete surface In individualcarton box 70 cmor less In master cartonbox 50 cmor less Onetime for 6faces 1 corner and 3edges 4 3 3 HA C32DCHG Table 4 ...

Page 34: ...ibration 2 0 G or less 10 to 55 Hz In X Y and Z directions Reciprocally for 30 minutes Resistance to impact In bare condition 100 cm 6 faces 4 edges onto P tile In individualcarton box 70 cmor less In master cartonbox 70 cmor less 6 faces 3 edges 1 corner onto concrete floor ...

Page 35: ...s Installing removingthebatterycover 3 000times Installing removingthestylus to fromthesilo 10 000times Opening closingthe CFcardslot cover 5 000times 40 000hours MainPCB Electronicsparts 30 000hours Batteries switches LCD module excludingjacks MTBF LCD 100 000hours Charginganddischargingcycleof batterypack 500times ApplicabletoHA C21BAT seenote Note The numberof the cycles isassumed with the cond...

Page 36: ...IO Powerswitch 5 000times Switch DIPswitch 10times ApplicabletoHA C61IO USB 500times RS 232C 500times No ofinstalling removingthe connector RS 422 100times ApplicabletoHA C61IO No ofinstalling removingACadaptorto fromthepower adaptorport 1 500times 4 4 3 HA C32DCHG Table 4 16 Item Specification Remark MTBF Electronics parts 50 000hours No ofinstalling removing the batterypack to from 5 000 times N...

Page 37: ...50 1 FCCPart15sub partC SAR IT 10M20 Yes Yes No IT 10M20BR Yes Yes Yes Note ConsultCASIOComputerCo Ltd forotherareas 4 5 2 HA C60IO HA C61IO Table 4 19 Compliance Standard Europe USA EN55022 1998 A1 2000 Class B EMC EN55024 1998 A1 2001 Class B FCCPart15BClassB Safety EN60950 UL60950 1 4 5 3 AD S42120AE AD S15050AE Table 4 20 Compliance Standard Europe USA EMC EN55022 EN55024 EN61000 FCC Part15B S...

Page 38: ...alP V C Core wire Finish of external shape 20 0 1A Insulator P V C Sheath Finishofexternalshape φ4 3 0 1mm Conductance resistance 0 12Ω morless Characteristics Insulationresistance 50MΩ or more Pinlayoutdiagramofcableforchainconnectionand short distance pin to pin straight connection Wiring Pin no Signal Pin no Signal 1 IRS 1 ORS 2 IRS 2 ORS 3 ISD 3 OSD 4 ISD 4 OSD 5 ORD 5 IRD 6 ORD 6 IRD Cradleat...

Page 39: ...0M3P by Sanyo Industrial Co Pin layout diagramofcable for chain connection and long distance pin to pin straight twist pair connection Wiring Pin no Signal Pin no Signal 1 IRS 1 ORS 2 IRS 2 ORS 3 ISD 3 OSD 4 ISD 4 OSD 5 ORD 5 IRD 6 ORD 6 IRD Cradleatlower position under the chain connection Cradleathigher position under the chain connection Fig 5 3 XXXXXX XXXXXX XXXXXX Viewfromside Viewfromtop Fig...

Page 40: ...ackup to avoid loss of data due to consumption of thebatteries Precautions for long term storage over one week Priortolong termstorage overoneweek alwaysback up datain the terminal to other memorystorage device In addition remove the lithium ion batterypack before storage This canminimize overly discharging the installed batterypack and minimize consumption of the memorybackup battery Do not store...

Page 41: ...a hammer nor stamp it If this is done the battery pack may be broken or deformed resulting ina short circuit and causingitto become hot smoke explode or ignite Do not hit or throw the batterypack If the protection means incorporated in thebattery pack is damaged the batterypack may be charged with an excessive current or voltage or have abnormal chemical reactions induced to cause it to become hot...

Page 42: ...r If this is done the batterypack will be quicklyheated or the contactseal maybe broken causing ittobecome hot smoke explode or ignite 2 If you are aware of an abnormal condition such asa smell excessive heat discoloration deformation etc during use charging and storage of the batterypack immediately remove it fromthe IT 10 and do not use it anymore If it continuouslyused withoutproper treatment t...

Page 43: ...etal chips water liquidchemicals enter inside theproduct immediately turn off the IT 10 remove the batterypack and then contact your CASIO distributor Memoryprotection 1 Contents of the IT 10 should alwaysbe backedup in personal computer to make a separate record from that on theterminal The contentsofthe memory may accidentally be lost due tobattery power consumption etc This also occurs whenthis...

Reviews: