Configuration File
The various setting values can be stored in a file and resumed. The setting file storage location and
its name are “\Documents and Settings\System Settings\OBRDRV.ini”. If there is no such the
setting file, the default values are used to initiate scanning.
Table 2.50
Symbol
ogy
Parameter Description
Range
Default Setting
1
1: Enable
Code39
2
2:
Enable NW-7
4
4: Enable
WPC
Addon
8
8:
Enable WPC
16
16: Enable
UPC-E
Addon
32
32: Enable
UPC-E
64
64: Enable
IDF
128
128: Enable
ITF
256
256: Enable
Code93
512
512: Enable
Code128
1024
1024: Enable
MSI
2048
2048: Enable
IATA
4096
4096: Enable GS1 DataBar
Omnidirectional.
8192
8192: Enable GS1 DataBar
Limited.
16384
16384: Enable GS1 DataBar
Expanded.
32768
32768 Enable GS1 DataBar
Stacked.
Re
ad
ab
le
B
ar
Co
de
READCODE Enable
or
disable
scanning the
symbologies.
(note 1)
65536
131071
65536 Enable GS1 DataBar
Expanded Stacked.
CODE39_MIN
Valid minimum digits
2
2
CODE39_MAX Valid
maximum
digits
52
52
0
0: Output Code39 bar code
with start and stop
characters.
1
1: Output Code39 bar code
without start and stop
characters.
2
2: Output Code39 bar code
after Full ASCII conversion
and with start and stop
characters.
C
ODE 39
Op
tion
CODE39_OUTFORMAT Output
format
3
0
3: Output Code39 bar code
after Full ASCII conversion
and without start and stop
characters.
Continue.
Summary of Contents for IT-800 Series
Page 173: ...173 Copyrights Tab This tab is for displaying the OS copyright information Figure 3 19 ...
Page 201: ...201 Date Tab This tab is for setting display format of date Figure 3 56 ...
Page 247: ...247 4 2 Games The terminal comes with two games Solitaire and Bubble Breaker Figure 4 2 ...
Page 255: ...255 4 5 Calculator The application can be used to operate nine digit calculator Figure 4 11 ...