11
—
TROUBLESHOOTING
Before the following solutions will be done, save data if possible.
SYMTOM
No Power
No display at all or wrong
display
No key input at all
SOLUTION
Replace batteries
Resolder
Replace it
Replace it
Replace it
Replace it
Replace it
Resolder
Replace it
CAUSE
Battery shortage
Poor soldering of the power supply
circuit
Defective LSI-1 or LSI-2
Defective Capacitor C8, C12, C13, or
C14
Defective TAB LSI
Defective heat seal
Defective LCD
Poor soldering LSI-1 or LSI2
Defective LSI-1 or LSI-2