[ 11 ] LCD test
[Function]
This test will check the LCD display.
In case of one time check only, the test can be ended by the judgment (OK or NG) of the operator.
The display can be switched by the touch of the panel. The display will not change to the next one
unless the panel is touched.
[Operation]
Press [OK] key or [NG] key to end the test when performing one time check.
"OK" = 1, "NG" = 9
Operation :
n
0
2
1
ST
n: 0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press "ESC" key)
[LCD]
Green
Blue
Reverse
check
Red
White
Black
Touch any place
in the panel.
Touch any place
in the panel.
Touch any place
in the panel.
Touch any place
in the panel.
Touch any place
in the panel.
Touch any place
in the panel.
Check (black
and white)
Shows the following colors and patterns in the display in the order of black, white, red, green, blue,
check and reverse check.
Returns to the normal display after the test, and waits for the input of [OK] or [NG] by the operator
(in case of one time check).
In case of continuous check, the test is ended manually upon the input of [ESC] key.
LCD
n021
LCD
OK
END
n021
[PRINT]
LCD
n021
LCD
OK
END
n021
Summary of Contents for QT-6000
Page 79: ... 77 8 14 ETHERNET CONTROLLER IC28 LAN91C113 8 14 1 Pin Assignment 8 14 2 Block Diagram ...
Page 105: ... 103 11 PCB LAYOUT MAIN PCB E820 1R PCB TOP VIEW ...
Page 106: ... 104 MAIN PCB E820 1R PCB BOTTOM VIEW ...
Page 135: ... 133 EXPLODED VIEW QT 6060D 2 11 17 14 15 20 Sales Option 16 5 6 12 13 18 19 8 7 10 3 1 4 9 5 ...
Page 150: ... 148 18 DRAWER DL 3616 ...
Page 152: ... 150 19 DRAWER DL 3617 ...