— 35 —
[ 11 ] LCD test
[Function]
This test will check the LCD display.
In case of one time check only, the test can be ended by the judgment (OK or NG) of the opera-
tor.
The display can be switched by the touch of the panel. The display will not change to the next
one unless the panel is touched.
[Operation]
Press [OK] key or [NG] key to end the test when performing one time check.
"OK" = 1, "NG" = 9
Operation : n 0 2 1 ST
n: 0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press "ESC" key)
[LCD]
Green
Blue
Reverse
check
Red
White
Black
Touch any place
in the panel.
Touch any place
in the panel.
Touch any place
in the panel.
Touch any place
in the panel.
Touch any place
in the panel.
Touch any place
in the panel.
Check (black
and white)
Shows the following colors and patterns in the display in the order of black, white, red, green,
blue, check and reverse check.
Returns to the normal display after the test, and waits for the input of [OK] or [NG] by the operator (in
case of one time check).
In case of continuous check, the test is ended manually upon the input of [ESC] key.
LCD
n021
LCD
OK
END
n021
[PRINT]
LCD
n021
LCD
OK
END
n021
Summary of Contents for QT-6100
Page 1: ...SERVICE MANUAL ELECTRONIC CASH REGISTER without price QT 6100 EX 819 AUG 2008 QT 6100 ...
Page 67: ... 65 8 11 ETHERNET CONTROLLER IC28 LAN91C113 8 11 1 Pin Assignment 8 11 2 Block Diagram ...
Page 92: ... 90 11 PCB LAYOUT MAIN PCB E819 1 PCB TOP VIEW ...
Page 93: ... 91 MAIN PCB E819 1 PCB BOTTOM VIEW ...
Page 94: ... 92 INTERFACE PCB E819 S1 PCB TOP VIEW BOTTOM VIEW LED PCB E820 LED PCB TOP VIEW BOTTOM VIEW ...
Page 108: ... 106 Model Name Board No Drawing No CASIO COMPUTER CO LTD QT 6100 EX 819 E820 LED LED ...
Page 120: ... 118 EXPLODED VIEW QT 6060D 2 11 17 14 15 20 Sales Option 16 5 6 12 13 18 19 8 7 10 3 1 4 9 5 ...
Page 135: ... 133 18 DRAWER DL 3616 ...
Page 137: ... 135 19 DRAWER DL 3617 ...