— 44 —
[ 23 ] Buzzer test
[Function]
This test will check the buzzer function.
Ring the one-shot buzzer.
[Operation]
Operation : n 0 9 2 ST
n: 0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press "ESC" key)
[LCD]
[PRINT]
BUZZ
n092
END
n092
BUZZ
n092
END
n092
[ 24 ] OBR test
[Function]
This is a scanner test. The test enters the wait mode for the scanner input, and waits only for
scanner.
The test determines the result between OK and NG by comparing the fixed data and the read
data.
Make sure to connect OBR (HHS-15) to COM 2.
* The fixed barcode is as follows.
[Operation]
Operation : 9 5 ST
To stop the test, press "ESC" key.
[LCD]
[PRINT]
OBR
95
OBR
OK
OBR ERR
xxxxxxxxxxxxxx
END
95
OBR
95
OBR
OK
OBR ERR
xxxxxxxxxxxxxx
END
95