— 3 —
2. Adjusting the gap between the print head and platen
This adjustment allows for optimal print quality.
2-1 Measuring the gap between the print head and platen
1.
Remove printer mechanism according to the procedure described in section 2,2.
2.
Using the clearance gauge, measure the gap (backlash) between the print head and the platen.
Notice:
When adjusting, install the four rubber sheets in the printer mechanism.
Fig. 1-1 Method for measuring the gap
Carriage and carriage guide
stay backlash
Head
Removal of
the backlash
Carriage
Platen
Gap
Fig. 1-2 Removal of the carriage and the carriage
guide stay backlash
3.
Measurements are taken within the left and right printing areas of the platen.
Measure at 3 to 5 locations while rotating the PF roller. Be careful to prevent anything from altering
the accuracy of the measurements taken and to avoid any warped areas of the gum roller.
4.
The standard gap should measure between 0.25 and 0.3mm (a range from 0.2 to 35mm can be
expected depending upon any variances).
Summary of Contents for SP-1300
Page 1: ... without price TECHNICAL MANUAL TERMINAL SLIP PRINTER FEB 2000 SP 1300 INDEX ...
Page 20: ... 18 Fig 3 1 Lubricated Areas 1 ...
Page 21: ... 19 Fig 3 2 Lubricated Areas 2 ...
Page 23: ... 21 1 Printer Assembly 1 1 Disassembly Drawing ...
Page 25: ... 23 2 Printer Mechanism 2 1 Disassembly Drawing ...
Page 26: ... 24 ...
Page 30: ... 28 4 Wiring Scheme of Printer ...
Page 31: ... 29 5 Main Logic Board 5 1 Circuit Diagram Main Logic Board 1 5 ...
Page 32: ... 30 Main Logic Board 2 5 ...
Page 33: ... 31 Main Logic Board 3 5 ...
Page 34: ... 32 Main Logic Board 4 5 ...
Page 35: ... 33 Main Logic Board 5 5 ...