— 5 —
TP7
VR200
TP2
Pad IF
TP3
TP4
VR700
TP6
TP5
VR300
VR301
BOTTOM VIEW
VCC2 Voltage Setting
Input
Input
Input
Output
Output
Connection Point
Signal
Connection
Point
Adjust
Result
3) Equipment Connection / Procedure
Adjust for 3.95
±
0.02V
reading on voltmeter.
Voltmeter
VR100
Set
Output
Voltmeter
TP1
TP1
TV-350