— 11 —
This connector is used to connect the printer to an external power source.
NOTE: Be sure to ground the frame ground (FG) screw on the board at the bottom of the unit. Ground
wire terminal hole diameter: 3.2 mm (.13"). Ground wire thickness: AWG 18 or equivalent.
A pulse specified by the ESC p command is output to the drawer kick-out connector. The host
can confirm the status of the input signal by using the GS a , GS r, or DLE EOT commands.
The host computer can check the drawer open/closed status with the DLE EOT, GS a , and GS r
commands.
Pin assignments:
See the table below.
Pin Number
1
+ power supply
2
GND
3
NC
Shell
Frame GND
Pin Number
Signal name
Direction
1
Frame GND
2
Drawer kick-out drive signal 1
(See "Drawer kick-out drive signal," below.)
Output
3
Drawer open/close signal
(See "Drawer open/closed signal," below.)
Input
4
+24
—
—
VDC
5
Drawer kick-out drive signal 2
(See "Drawer kick-out drive signal," below.)
Output
6
Signal GND
—
Input signal level:
LOW = 0 V
HIGH = 2 to 5 V (at connector pin 3)
2
3
1
Signal Name
Power Supply Connector
Drawer Kick-Out Connector
Power supply connector pin assignments
Drawer kick-out connector pin assignments
Drawer open/closed signal
Summary of Contents for UP-250
Page 1: ...EXTERNAL PRINTER FEB 2000 MODEL UP 250 without price TECHNICAL MANUAL ...
Page 95: ... 86 END END Yes No Action 4 Replace main PCB Replace printer OK Action 4 mechanism assembly ...
Page 136: ... 127 ...
Page 149: ... 140 Main Circuit Board Parts Layout ...
Page 150: ... 141 RS 232 Serial Interface Circuit Board Parts Layout ...
Page 151: ... 142 IEEE 1284 Parallel Interface Circuit Board Parts Layout ...
Page 152: ...RS 485 Serial Interface Circuit Board Parts Layout 143 ...
Page 160: ... 151 Case Unit Lubrication Points Diagram 4 G 31 4 G 31 3 G 31 3 G 31 ...
Page 163: ... 154 EXPLODED DIAGRAM FOR TM U200B U210B NO 1 ...
Page 164: ... 155 EXPLODED DIAGRAM FOR TM U200B U200PB U210B U210PB NO 2 ...