User Maintenance
E-28
4.
Loosen the lamp cover screw, and then
remove the lamp cover.
5.
Loosen the three screws indicated by
an
mark.
6.
Use the lamp cartridge handle to pull
the lamp cartridge from the projector.
7.
Insert the new lamp cartridge as far as
it will go, as shown in the illustration.
z
After inserting the lamp cartridge, lay its
handle down in the position shown in
the illustration under step 5 on this
page.
z
Take care to avoid touching the lamp
(glass) and the mirrors inside the
projector. Doing so can cause the lamp
to rupture, shorten lamp life, and
otherwise affect lamp performance.
8.
Secure the lamp cartridge with the
three screws.
9.
Return the lamp cover to its original
position, and secure it with the screw.
z
After replacing the lamp, be sure to
perform the procedure under “Resetting
the Lamp Time” on page E-29.