CAMcourse
Page 6
Alterations / Errors Reserved 16/Wo/266D
Cassens & Plath GmbH, Am Lunedeich 131, D-27572 Bremerhaven, Germany, tel +49(0)471 483 999 0, fax +49(0)471 483 999 10
www.cassens-plath.de
,
sales@cassens-plath.de
Main Indicator
(Measures Junction Box 1: w125xh80xd60mm)
Screening of cables have to been fixed
in cable glants!
Camera
(Measures Junction Box 2: w100xh65xd35mm)
To Junction Box 2 (Camera):
9)
+12V DC
10)
GND
11)
GND
12)
Video
Cable, yard supply!:
4x0.14² min., twisted pairs, shielded, max. 40m
To 2nd Monitor (optional):
5)
+12V DC
6)
GND
7)
GND
8)
Video
Power supply:
13) +24V DC
14) GND
15) +24V DC emergency
16) GND
Emergency supply (15 + 16) only needed if
seperated from main supply (13 + 14).
Cable, yard supply!:
2x0.25² min., twisted pair, shielded, max. 5m
(2 pieces for main- and emergency supply)
To Junction Box 1 (Monitor):
1)
Video (yellow)
2)
GND (white)
3)
GND (black)
4)
+12V DC (red)
Cable, yard supply!:
4x0.14² min., twisted pairs, shielded, max. 40m
(refer junction box 1)
To Monitor:
1)
+12V DC
2)
GND
3)
GND
4)
Video