I
- 7 -
SERVICING
Adjustment of the starting microswitch for the vertical cylinder (see Fig. 9)
If despite pressing the button S the descent of the bung is very harsh, bring
the starter microswitch nearer to the limit stop by adjusting the blocking nuts.
Adjustment of the limit stop on the vertical cylinder (See Fig. 9)
At the end of the wedge insertion
the limit stop activates
the microswitch which
controls the return of the cylinder.
If the wedge has not been inserted fully
into the moulding screw the limit stop so as to increase the travel.
Removing the sliding table
Unscrew the locking handle and release the table by lifting it with the two fence
tilt adjustment buttons.
Servicing the wedge distribution area
From time to time remove the distributor head (H) and clean all the area in
contact with the front of the wedge cartridge with a stiff brush used dry.
Service and greasing
If movement becomes sticky oil the horizontal bars (use 20/20 SAE oil).
Cleaning:
Do not use any wet materials to remove excess glue that has collected
on the machine.
It helps to remove the glues if the area is sprayed
with a silicone grease prior to the machine being used.
To remove the distributor head (H) undo the locking screw and remove
it by pulling it upwards.
Remove the head, clean the area underneath
it with the aid of a small,
stiff brush.
Do not
use
dry cleaning fluid
IMPORTANT:
When replacing the distributor head only tighten
the locking screw gently.
Do not
overtighten.
When the
"maintenance"
indicator illuminates apply grease to the hammer area.
After greasing press the arrow
and RAZ keys simultaneously in order to
extinguish the
"maintenance"
indicator.