background image

NOR INS REV 5 Nov 2017

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Norvik 5 

Multi-fuel stove 

80% Efficient 

 

This stove is designed for intermittent use and is tested and manufactured as a 

closed multi-fuel appliance. Cast Tec recommend that this appliance is 

installed by a HETAS registered Installation engineer or competent person. 

Failure to comply will invalidate the manufacturer’s warranty. 

 

 

 

In

st

a

lla

tio

n

 &

 O

p

e

ra

tin

g

 I

n

st

ru

ct

io

n

 

 

English 

Summary of Contents for NORVIK 5

Page 1: ...ittent use and is tested and manufactured as a closed multi fuel appliance Cast Tec recommend that this appliance is installed by a HETAS registered Installation engineer or competent person Failure t...

Page 2: ...Lighting the fire Firebox linings and baffle Running temperatures Cleaning Maintenance Woodburning tips theory INSTALLATION INSTRUCTIONS Building regulations Positioning clearances Chimney Flue connec...

Page 3: ...ing this time as airing the room will allow this to disappear Step 1 Open the air control fully using the tool Glove Step 2 Place rolled up crumpled newspaper at the back of the stove Place small tind...

Page 4: ...r containing the set screw Turning the anti clockwise slacken the set screw until the door handle becomes loose once loose turn the handle the correct way as per below drawing below on completion slow...

Page 5: ...Fully close the air control and keep the stove door closed Move any combustibles away from the stove and chimney Check any other rooms that the chimney passes through and move and combustibles away fr...

Page 6: ...make sure there is no build up of deposits that will restrict the exit of the flue gases Note The stove must not be modified in any way Any changes will invalidate your warranty Any replacement parts...

Page 7: ...t be used in the same room as the appliance unless adequate additional ventilation is provided Other heating appliances requiring air for combustion shall not be used in the same room as the appliance...

Page 8: ...d on the clearance figures shown in figure and reference should be made to building regulations and any rules in force at the time of installation Chimney Requirements An existing chimney or a new flu...

Page 9: ...ket to support the flue The 5 125mm flue pipe required from the stove to the register plate Operational Problems Blackened Glass The wood is too damp Only use wood that has been stored for at least 12...

Page 10: ...NOR INS REV 5 Nov 2017 Stove Dimensions...

Page 11: ...l Customer name and address Installer Name Registration Number Date Who certifies that this installation is safe has been demonstrated to the householder conforms to current building regulations has a...

Page 12: ...s which generally apply in the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Cle...

Page 13: ...NOR INS REV 5 Nov 2017 Don t forget to register your stove to activate your warranty...

Reviews: