Page C3
Automatic Inhibit
Euro-MERiDIAN is designed to
automatically disable certain
functionality. The factory default
settings are as shown below:
Intruder
Alarm Signal
After 3* unconfirmed
alarms in the same area or 1
confirmed alarm.
Tamper
Alarm Signal
After 3* unconfirmed
alarms in the same area or 1
confirmed alarm.
Keypad
After 23 keypresses without
entering a valid code, keys
are disabled for 90 seconds.
After reinstatement, this will
be repeated after each 7
keypresses until a valid code
is entered.
Tag Reader
After 6 presentations of an
invalid tag, the reader will be
disabled for 90 seconds. After
reinstatement, this will be
repeated for each invalid tag
until a valid tag is used.
*
This figure is programmable by the
installing company